Literature DB >> 8968267

Phase I study of the safety and pharmacologic effects of diaspirin cross-linked hemoglobin solution.

R J Przybelski1, E K Daily, J C Kisicki, C Mattia-Goldberg, M J Bounds, W A Colburn.   

Abstract

OBJECTIVE: To evaluate the safety, pharmacokinetics, and pharmacodynamics of diaspirin cross-linked hemoglobin solution (DCLHb) in normal, healthy volunteers.
DESIGN: Randomized, double-blind, controlled, crossover study.
SETTING: Phase I research facility of a contract research organization. PATIENTS: Twenty-four healthy adult volunteers.
INTERVENTIONS: Diaspirin cross-linked hemoglobin solution (25, 50, or 100 mg/kg) or equal volume of lactated Ringer's solution was infused on day 1; the alternate solution was infused 6 days later. Laboratory analyses, electrocardiograms, and Holter and telemetry monitoring were performed to assess organ function, pharmacokinetics, and potential toxicity. Vital signs, pulse oximetry, laser Doppler flowmetry, and toe temperature were measured to evaluate diaspirin cross-linked hemoglobin solution's pharmacodynamic effects.
MEASUREMENTS AND MAIN RESULTS: There were no serious adverse events associated with diaspirin cross-linked hemoglobin solution infusion. Abdominal pain occurred in three subjects after control infusion and in six subjects after diaspirin cross-linked hemoglobin solution infusion; no treatment was required. A dose-related increase in lactic dehydrogenase (LDH)-5 isoenzyme concentrations was observed in 12 subjects after diaspirin cross-linked hemoglobin solution infusion. There were no associated increases in the circulating concentrations of total LDH, aspartate aminotransferase, alanine aminotransferase, or alkaline phosphatase. Total serum creatine kinase concentrations increased significantly after infusion of 100 mg/kg of diaspirin cross-linked hemoglobin solution; the isoenzyme creatine kinase-myocardial band (CK-MB) was not increased, nor were there any abnormal electrocardiogram findings. There were no differences in laser Doppler, pulse oximetry, or toe temperature measurements during or after either infusion. The half-life of diaspirin cross-linked hemoglobin solution was 2.5 hrs for the 25- and 50-mg/kg doses and 3.3 hrs for the 100-mg/kg dose. A dose-related increase in blood pressure occurred with diaspirin cross-linked hemoglobin solution.
CONCLUSIONS: Diaspirin cross-linked hemoglobin solution doses of 25, 50, and 100 mg/kg are well tolerated, without evidence of organ dysfunction or toxicity. Diaspirin cross-linked hemoglobin solution's pressor effect is without evidence of decreased peripheral perfusion. Further investigations of its use in certain patient populations are warranted.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8968267     DOI: 10.1097/00003246-199612000-00011

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  9 in total

1.  The clinical trials of diaspirin cross-linked hemoglobin (DCLHb) in severe traumatic hemorrhagic shock: the tale of two continents.

Authors:  Edward P Sloan
Journal:  Intensive Care Med       Date:  2003-03       Impact factor: 17.440

Review 2.  Drugs for increasing oxygen and their potential use in doping: a review.

Authors:  Aurelie Gaudard; Emmanuelle Varlet-Marie; Francoise Bressolle; Michel Audran
Journal:  Sports Med       Date:  2003       Impact factor: 11.136

3.  Role of nitric oxide scavenging in vascular response to cell-free hemoglobin transfusion.

Authors:  Kenji Sampei; John A Ulatowski; Yoshio Asano; Herman Kwansa; Enrico Bucci; Raymond C Koehler
Journal:  Am J Physiol Heart Circ Physiol       Date:  2005-05-13       Impact factor: 4.733

4.  Hemolysis-associated endothelial dysfunction mediated by accelerated NO inactivation by decompartmentalized oxyhemoglobin.

Authors:  Peter C Minneci; Katherine J Deans; Huang Zhi; Peter S T Yuen; Robert A Star; Steven M Banks; Alan N Schechter; Charles Natanson; Mark T Gladwin; Steven B Solomon
Journal:  J Clin Invest       Date:  2005-11-17       Impact factor: 14.808

5.  Acute kidney function and morphology following topload administration of recombinant hemoglobin solution.

Authors:  Alexandre Fabricio Martucci; Ana Carolina Carvalho Ferreira Abreu Martucci; Pedro Cabrales; Paulo do Nascimento; Marcos Intaglietta; Amy G Tsai; Yara Marcondes Machado Castiglia
Journal:  Artif Cells Nanomed Biotechnol       Date:  2016-10-31       Impact factor: 5.678

Review 6.  Doping with artificial oxygen carriers: an update.

Authors:  Yorck Olaf Schumacher; Michael Ashenden
Journal:  Sports Med       Date:  2004       Impact factor: 11.136

Review 7.  Comparison of the Pharmacokinetic Properties of Hemoglobin-Based Oxygen Carriers.

Authors:  Kazuaki Taguchi; Keishi Yamasaki; Toru Maruyama; Masaki Otagiri
Journal:  J Funct Biomater       Date:  2017-03-18

Review 8.  Nanomedicines: A Potential Treatment for Blood Disorder Diseases.

Authors:  Nan Zhang; Ming-Yuan Wei; Qiang Ma
Journal:  Front Bioeng Biotechnol       Date:  2019-11-28

9.  Shock index and prediction of traumatic hemorrhagic shock 28-day mortality: data from the DCLHb resuscitation clinical trials.

Authors:  Edward P Sloan; Max Koenigsberg; James M Clark; William B Weir; Nora Philbin
Journal:  West J Emerg Med       Date:  2014-09-25
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.