Literature DB >> 8962944

An albumin-coated polyester arterial graft: in vivo assessment of biocompatibility and healing characteristics.

Y Marois1, N Chakfé, R Guidoin, R C Duhamel, R Roy, M Marois, M W King, Y Douville.   

Abstract

The albumin-coated vascular graft (ACG) and its uncoated polyester substrate, the Vascular II (V-II), were evaluated in terms of biocompatibility and biofunctionality using two in vivo animal studies. Biocompatibility and immunoreactivity were assessed by implanting intraperitoneally in the rat small segments of the ACG and the V-II graft and harvesting them with their surrounding tissue 3d, 1, 2 and 4 weeks later. Cytofluorometric determination of total T cells (CD3), the ratio of CD4/CD8 subsets and the percentage of IL-2 receptor-positive T cells in the peripheral blood has revealed that no significant difference in any of the T cell populations was found between the ACG and the V-II graft. The cellular reactivity of the ACG in terms of acid phosphatase activity at the implant side was significantly greater at 3 d but not at longer periods. Biofunctionality was evaluated by implanting both grafts as a thoracoabdominal vascular bypass in dogs for 11 different periods ranging from 4 h to 6 months. The rate of albumin resorption was such that traces were still present at 1 month, but no longer observable at 2 months. Tissue incorporation into the graft wall was earlier for the V-II (2 weeks) than for the ACG (4 weeks), which showed complete encapsulation, tissue incorporation and endothelialization after 2 months in vivo. Only small differences were observed between both grafts in terms of platelet and fibrin uptake on the luminal surface. The prostacyclin/thromboxane A2 ratio increased to a level higher that 1.0 aorta within 1 month for the V-II and 4 months for the ACG. In conclusion, the Bard ACG has demonstrated excellent biocompatibility in terms of blood T cell behaviour and acid phosphatase activity at the implant site. Finally, its healing response is equivalent to that of the uncoated Dacron prosthesis once the albumin coating has been resorbed.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8962944     DOI: 10.1016/0142-9612(96)80749-6

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  13 in total

Review 1.  The blood compatibility challenge. Part 2: Protein adsorption phenomena governing blood reactivity.

Authors:  John L Brash; Thomas A Horbett; Robert A Latour; Pentti Tengvall
Journal:  Acta Biomater       Date:  2019-06-18       Impact factor: 8.947

2.  Probing Albumin Adsorption onto Calcium Phosphates by XPS and ToF-SIMS.

Authors:  J E Baio; T Weidner; G Interlandi; C Mendoza-Barrera; H E Canavan; R Michel; D G Castner
Journal:  J Vac Sci Technol B Nanotechnol Microelectron       Date:  2011-07

3.  Preclinical evaluation of the thrombogenicity and endothelialization of bare metal and surface-coated neurovascular stents.

Authors:  S Krajewski; B Neumann; J Kurz; N Perle; M Avci-Adali; G Cattaneo; H P Wendel
Journal:  AJNR Am J Neuroradiol       Date:  2014-09-25       Impact factor: 3.825

4.  Time-dependent conformational changes in adsorbed albumin and its effect on platelet adhesion.

Authors:  Balakrishnan Sivaraman; Robert A Latour
Journal:  Langmuir       Date:  2012-01-17       Impact factor: 3.882

Review 5.  Nitric oxide-releasing/generating polymers for the development of implantable chemical sensors with enhanced biocompatibility.

Authors:  Yiduo Wu; Mark E Meyerhoff
Journal:  Talanta       Date:  2007-06-28       Impact factor: 6.057

6.  The adherence of platelets to adsorbed albumin by receptor-mediated recognition of binding sites exposed by adsorption-induced unfolding.

Authors:  Balakrishnan Sivaraman; Robert A Latour
Journal:  Biomaterials       Date:  2009-10-27       Impact factor: 12.479

7.  Novel polymeric scaffolds using protein microbubbles as porogen and growth factor carriers.

Authors:  Ashwin Nair; Paul Thevenot; Jagannath Dey; Jinhui Shen; Man-Wu Sun; Jian Yang; Liping Tang
Journal:  Tissue Eng Part C Methods       Date:  2010-02       Impact factor: 3.056

8.  Does Triplex Vascular Prosthesis Contribute to Reducing the Inflammatory Reaction after Surgical Repair of Abdominal Aortic Aneurysms?

Authors:  Naoto Fukunaga; Takehiko Matsuo; Tadaaki Koyama
Journal:  Ann Vasc Dis       Date:  2016-04-06

9.  An omniphobic lubricant-infused coating produced by chemical vapor deposition of hydrophobic organosilanes attenuates clotting on catheter surfaces.

Authors:  Maryam Badv; Iqbal H Jaffer; Jeffrey I Weitz; Tohid F Didar
Journal:  Sci Rep       Date:  2017-09-14       Impact factor: 4.379

Review 10.  Obstacles in haemocompatibility testing.

Authors:  W van Oeveren
Journal:  Scientifica (Cairo)       Date:  2013-05-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.