Literature DB >> 8960497

Balloon dilatation of the pulmonary valve in a patient with pulmonary atresia and intact ventricular septum using a commercially available radiofrequency catheter.

T Akagi1, K Hashino, Y Maeno, M Ishii, T Sugimura, T Kawano, H Kato.   

Abstract

Using a commercially available 5F deflectable radiofrequency catheter, we have succeeded in percutaneous valvotomy of an imperforate pulmonary valve and consecutive balloon dilatation in a baby with pulmonary atresia and intact ventricular septum. After the procedure, right ventricular systolic pressure fell from 125 mmHg to 65 mmHg, and right ventriculography demonstrated anterograde blood flow into the pulmonary arteries. There were no major complications. Doppler echocardiography at 1 year after the procedure demonstrated a pressure gradient across the pulmonary valve of 20 mmHg with mild pulmonary and tricuspid regurgitations.

Entities:  

Mesh:

Year:  1997        PMID: 8960497     DOI: 10.1007/s002469900112

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  2 in total

1.  Pulmonary Atresia with Intact Ventricular Septum.

Authors:  P. Syamasundar Rao
Journal:  Curr Treat Options Cardiovasc Med       Date:  2002-08

2.  Use of radiofrequency then stent implantation for recanalization of complete aorta coarctation.

Authors:  Y Almashham; N Dahdah; J Miro
Journal:  Pediatr Cardiol       Date:  2007-09-21       Impact factor: 1.655

  2 in total