Literature DB >> 8960435

Long-term recording of cardiac output via an implantable haemodynamic monitoring device.

A Ohlsson1, T Bennett, F Ottenhoff, C Bitkover, B Kjellström, R Nordlander, H Aström, L Rydén.   

Abstract

Long-term monitoring of central haemodynamics with implanted monitoring systems might be valuable in managing heart failure patients. Such systems offer an opportunity for repeated 'semi-invasive' cardiac output determinations according to the Fick principle. Five patients, four with chronic heart failure and one with chronic pulmonary disease, underwent supine exercise testing during cardiac catheterization at 0, 2, 6 and 11 months after implantation of a right ventricular mixed venous oxygen saturation sensor connected to an implantable haemodynamic monitor. The monitor provided a continuous measure of oxygen saturation via a radio-telemetry link to a metabolic cart capable of measurement of breath-by-breath oxygen consumption. Cardiac output was computed using oxygen consumption, mixed venous oxygen saturation, arterial oxygen saturation by pulse oximetry and haemoglobin oxygen capacity. Biosensor-derived oxygen saturation compared to blood samples from the pulmonary artery showed an excellent correlation over time, r2 = 0.94 (implant), r2 = 0.91 (6-11 months). There was a strong correlation between semi-invasive-determined cardiac output using the biosensor and the invasive technique, which persisted over the entire follow-up period. Repeated semi-invasive cardiac output measurements using an implanted haemodynamic monitoring system in chronic heart failure patients is feasible and the data may be of value for optimizing therapy.

Entities:  

Mesh:

Year:  1996        PMID: 8960435     DOI: 10.1093/oxfordjournals.eurheartj.a014810

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  4 in total

Review 1.  Theory and applications of biotelemetry.

Authors:  Nihal Fatma Güler; Elif Derya Ubeyli
Journal:  J Med Syst       Date:  2002-04       Impact factor: 4.460

Review 2.  Who should pay for home monitoring of heart failure?

Authors:  Monica Colvin Adams; Syed Sohail Ali
Journal:  Curr Cardiol Rep       Date:  2006-05       Impact factor: 2.931

3.  Therapeutic implications of implantable device-based monitoring of patients with heart failure.

Authors:  Eric Popjes; John P Boehmer
Journal:  Curr Treat Options Cardiovasc Med       Date:  2008-09

Review 4.  Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors.

Authors:  Deirdre M Mooney; Erik Fung; Rahul N Doshi; David M Shavelle
Journal:  Front Physiol       Date:  2015-10-07       Impact factor: 4.566

  4 in total