Literature DB >> 8959268

Confirmation and initial documentation of thoracic and abdominal aortic helical flow. An ultrasound study.

L J Frazin1, M J Vonesh, K B Chandran, T Shipkowitz, A S Yaacoub, D D McPherson.   

Abstract

Aortic helical flow may play an important role in plaque deposition, dissection formation, and organ perfusion. The authors have previously demonstrated, using in vitro flow models and transesophageal echocardiography, that helical flow begins in the mammalian aortic arch and continues into the descending thoracic aorta. The purpose of this study was to confirm thoracic aortic helical flow and document its extent into the abdominal aorta using direct measurements. Twelve mongrel dogs underwent surgery with exposure of the abdominal aorta up to the diaphragm. Six of the 12 underwent further thoracotomy with thoracic aorta exposure. Color Doppler ultrasound images were obtained using a 5 megaHz esophageal transducer, hand held, directly applied, and visually aligned for transverse aortic imaging. Helical flow was considered present with the appearance of red/blue hemicircles during a systolic wave when the aorta was imaged transversely. All six dogs that had thoracotomy showed clockwise thoracic aortic helical flow (along the direction of blood flow) at the retro left ventricular region. In all dogs, clockwise helical flow was demonstrated to and immediately beyond the renal arteries. In 11 of 12 dogs, clockwise helical flow was demonstrated 7 cm below the renal arteries. The study confirms the presence of helical flow in the thoracic aorta and documents its extent into the abdominal aorta below the level of the renal arteries. The teleologic flow pattern of mammals may extend to other classes of vertebrates and must be accounted for in studies of endothelial shear and flow separation. In addition, tangential velocities imparted by helical flow may affect organ perfusion.

Entities:  

Mesh:

Year:  1996        PMID: 8959268     DOI: 10.1097/00002480-199642060-00006

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  8 in total

1.  Differences in aortic vortex flow pattern between normal and patients with stroke: qualitative and quantitative assessment using transesophageal contrast echocardiography.

Authors:  Jang-Won Son; Geu-Ru Hong; Woosol Hong; Minji Kim; Helene Houle; Mani A Vannan; Gianni Pedrizzetti; Namsik Chung
Journal:  Int J Cardiovasc Imaging       Date:  2015-11-30       Impact factor: 2.357

2.  Computational fluid dynamic simulations of image-based stented coronary bifurcation models.

Authors:  Claudio Chiastra; Stefano Morlacchi; Diego Gallo; Umberto Morbiducci; Rubén Cárdenes; Ignacio Larrabide; Francesco Migliavacca
Journal:  J R Soc Interface       Date:  2013-05-15       Impact factor: 4.118

3.  Retrograde blood flow in the aortic arch determined by transesophageal Doppler ultrasound.

Authors:  S Svedlund; R Wetterholm; R Volkmann; K Caidahl
Journal:  Cerebrovasc Dis       Date:  2008-11-15       Impact factor: 2.762

Review 4.  Functional assessment of thoracic aortic aneurysms - the future of risk prediction?

Authors:  Pouya Youssefi; Rajan Sharma; C Alberto Figueroa; Marjan Jahangiri
Journal:  Br Med Bull       Date:  2017-01-01       Impact factor: 4.291

Review 5.  Haemodynamics and Flow Modification Stents for Peripheral Arterial Disease: A Review.

Authors:  Efstratios Kokkalis; Nicolas Aristokleous; J Graeme Houston
Journal:  Ann Biomed Eng       Date:  2015-10-14       Impact factor: 3.934

6.  Improvement of hemodynamic performance using novel helical flow vena cava filter design.

Authors:  Ying Chen; Peng Zhang; Xiaoyan Deng; Yubo Fan; Yubin Xing; Ning Xing
Journal:  Sci Rep       Date:  2017-01-23       Impact factor: 4.379

7.  Helical Flow Component of Left Ventricular Assist Devices (LVADs) Outflow Improves Aortic Hemodynamic States.

Authors:  Qi Zhang; Bin Gao; Yu Chang
Journal:  Med Sci Monit       Date:  2018-02-12

8.  The Hydrodynamics of a Swirling Blood Flow in the Left Heart and Aorta.

Authors:  A V Agafonov; E A Talygin; L A Bockeria; A Yu Gorodkov
Journal:  Acta Naturae       Date:  2021 Oct-Dec       Impact factor: 1.845

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.