Noninvasive method for measuring the electrical properties of deep tissues using an open-ended coaxial probe.

A Aimoto1, T Matsumoto.   

Abstract

A new noninvasive method of measuring the structure and the electrical properties of bilayered biological tissues was evaluated as a potentially useful diagnostic means for detecting changes in subcutaneous tissues. First, the input impedance of an open-ended coaxial probe radiating into a bilayered model was calculated using a full-wave method, the results showed that the evanescent higher order modes do not have a significant influence on the reflection coefficient of muscle layer surface. Then, it was clearly proven that the phase shift and the modulus of the reflection coefficient of muscle layer surface depending on the frequency are useful to estimate the thickness of fat layer and the electrical properties of muscle respectively. The experimental results showed an excellent agreement with the theoretical relationship between the phase shift and the thickness. The sensitivity of estimation of the electrical properties of muscle was shown to be not enough for differentiating between normal and diseased deep tissue because of noises from the experimental systems.

Mesh:

Year:  1996        PMID: 8953556     DOI: 10.1016/s1350-4533(96)00026-4

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  6 in total

1.  Control of lower extremity edema in patients with diabetes: Double blind randomized controlled trial assessing the efficacy of mild compression diabetic socks.

Authors:  Stephanie C Wu; Ryan T Crews; Melissa Skratsky; Julia Overstreet; Sai V Yalla; Michelle Winder; Jacquelyn Ortiz; Charles A Andersen
Journal:  Diabetes Res Clin Pract       Date:  2017-02-27       Impact factor: 5.602

2.  Movement, Function, Pain, and Postoperative Edema in Axillary Web Syndrome.

Authors:  Linda A Koehler; Anne H Blaes; Tuffia C Haddad; David W Hunter; Alan T Hirsch; Paula M Ludewig
Journal:  Phys Ther       Date:  2015-05-14

3.  Spatial and Temporal Variability of Upper Extremity Edema Measures After Breast Cancer Surgery.

Authors:  Linda A Koehler; Harvey N Mayrovitz
Journal:  Lymphat Res Biol       Date:  2018-11-14       Impact factor: 2.589

4.  Arm, Leg, and Foot Skin Water in Persons With Diabetes Mellitus (DM) in Relation to HbA1c Assessed by Tissue Dielectric Constant (TDC) Technology Measured at 300 MHz.

Authors:  Harvey N Mayrovitz; Irina Volosko; Bansari Sarkar; Naushira Pandya
Journal:  J Diabetes Sci Technol       Date:  2016-08-03

5.  A randomized controlled trial comparing two types of pneumatic compression for breast cancer-related lymphedema treatment in the home.

Authors:  Caroline E Fife; Suzanne Davey; Erik A Maus; Renie Guilliod; Harvey N Mayrovitz
Journal:  Support Care Cancer       Date:  2012-05-02       Impact factor: 3.603

6.  Sensor-Based Detection of the Severity of Hyperkeratosis in the Teats of Dairy Cows.

Authors:  Susanne Demba; Gundula Hoffmann; Christian Ammon; Sandra Rose-Meierhöfer
Journal:  Sensors (Basel)       Date:  2018-11-14       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.