Literature DB >> 8951905

Frequency of extra-cardiac activity and its effect on 99Tcm-MIBI cardiac SPET interpretation.

P K Rehm1, F B Atkins, H A Ziessman, S E Green, E A Akin, L M Fox, D J Hixson.   

Abstract

There are limited published data concerning the frequency and relative intensity of abdominal activity on 99Tcm-methoxyisobutyl isonitrile (99Tcm-MIBI) myocardial perfusion scans and its effect on interpretation. We undertook a blinded prospective study to evaluate (1) the frequency and intensity of abdominal activity on single photon emission tomography (SPET) scans, (2) its effect on separate evaluation of rest and stress SPET images, and (3) its effect on clinical interpretation. Patients undergoing one-day rest-stress 99Tcm-MIBI scans were randomized to receive 99Tcm-MIBI obtained from one of two radiopharmacies. The rest plus exercise or rest plus intravenous dipyridamole scans of 303 patients were scored separately by three physicians for (1) intensity of abdominal activity and (2) its effect on scan evaluation. Nuclear reports generated independently of the blinded evaluation were reviewed to assess the effect of abdominal activity on clinical interpretation. There were no statistical differences between pharmacies. Abdominal activity was uncommon on the exercise but common on the rest and dipyridamole scans. The exercise scans differed from the rest and dipyridamole scans in the subgroups: intensity of abdominal activity equal to myocardium, and greater than myocardium (P < 0.001). There was no difference between the rest and dipyridamole scans. The effect on evaluation was moderate in 5% of the exercise, 46% of the dipyridamole and 37% of the rest scans, and severe in 1% of the exercise, 3% of the dipyridamole and 12% of the rest scans. Rest differed from exercise (P < 0.001) and from dipyridamole (P < 0.05). There was no difference between the dipyridamole and exercise scans. Based on the clinical reports, abdominal activity was a limitation to scan interpretation for 20 patients; in 5, the inferior wall could not be evaluated. Although abdominal activity was frequently observed on both the dipyridamole and rest scans, it was a limitation to clinical interpretation in a small fraction of the patients.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8951905     DOI: 10.1097/00006231-199610000-00005

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  12 in total

1.  Comparison of image quality, myocardial perfusion, and left ventricular function between standard imaging and single-injection ultra-low-dose imaging using a high-efficiency SPECT camera: the MILLISIEVERT study.

Authors:  Andrew J Einstein; Ron Blankstein; Howard Andrews; Mathews Fish; Richard Padgett; Sean W Hayes; John D Friedman; Mehreen Qureshi; Harivony Rakotoarivelo; Piotr Slomka; Ryo Nakazato; Sabahat Bokhari; Marcello Di Carli; Daniel S Berman
Journal:  J Nucl Med       Date:  2014-06-30       Impact factor: 10.057

2.  Intense moving intestinal activity as a source of artifact on myocardial perfusion SPECT study.

Authors:  Arpit Shah; Ernest DePuey; Marvin Friedman
Journal:  J Nucl Cardiol       Date:  2015-03-27       Impact factor: 5.952

3.  Regadenoson pharmacologic stress for myocardial perfusion imaging: a three-way comparison between regadenoson administered at peak exercise, during walk recovery, or no-exercise.

Authors:  Randall C Thompson; Harshal Patil; Elaine C Thompson; Gregory S Thomas; Mohammed Al-Amoodi; Kevin F Kennedy; Kevin A Bybee; A Iain McGhie; James H O'Keefe; Lisa Oakes; Timothy M Bateman
Journal:  J Nucl Cardiol       Date:  2012-12-12       Impact factor: 5.952

4.  The effects of solid food in prevention of intestinal activity in Tc-99m tetrofosmin myocardial perfusion scintigraphy.

Authors:  Adil Boz; Firat Gungor; Binnur Karayalçin; Akin Yildiz
Journal:  J Nucl Cardiol       Date:  2003 Mar-Apr       Impact factor: 5.952

5.  Treadmill exercise during adenosine infusion is safe, results in fewer adverse reactions, and improves myocardial perfusion image quality.

Authors:  G S Thomas; N V Prill; H Majmundar; R R Fabrizi; J J Thomas; C Hayashida; S Kothapalli; J L Payne; M M Payne; M I Miyamoto
Journal:  J Nucl Cardiol       Date:  2000 Sep-Oct       Impact factor: 5.952

6.  New protocol of myocardial SPECT imaging with technetium-99m sestamibi for reducing the time interval between rest and adenosine stress phases.

Authors:  Hajime Monzen; Masatake Hara; Akira Nakanishi; Makoto Hirata; Takatoshi Suzuki; Makoto Ogasawara; Hirokazu Higuchi; Hisato Kobayashi; Rumio Yuki; Kunihiko Hirose
Journal:  Radiol Phys Technol       Date:  2008-12-12

7.  Long-term prognostic value of early poststress (99m)Tc-tetrofosmin lung uptake during exercise (SPECT) myocardial perfusion imaging.

Authors:  Panagiotis Georgoulias; Ioannis Tsougos; Varvara Valotassiou; Chara Tzavara; Petros Xaplanteris; Nikolaos Demakopoulos
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-12-17       Impact factor: 9.236

8.  Reduction of infracardiac intestinal activity by a small amount of soda water in technetium-99m tetrofosmin myocardial perfusion scintigraphy with adenosine stress.

Authors:  Masatake Hara; Hajime Monzen; Rie Futai; Koichi Inagaki; Hisashi Shimoyama; Masaru Morikawa; Nobuyoshi Tomioka; Takashi Konishi; Yutaka Watanabe; Rumio Yuki; Hisato Kobayashi; Kunihiko Hirose
Journal:  J Nucl Cardiol       Date:  2008-03-06       Impact factor: 5.952

9.  Feasibility of a rapid protocol of 1-day single-isotope rest/adenosine stress Tc-99m sestamibi ECG-gated myocardial perfusion imaging.

Authors:  Futoshi Tadehara; Hideya Yamamoto; Shuji Tsujiyama; Toshihide Hinoi; Shusuke Matsuo; Naoya Matsumoto; Yuichi Sato; Nobuoki Kohno
Journal:  J Nucl Cardiol       Date:  2008 Jan-Feb       Impact factor: 5.952

10.  The problem of radiotracer abdominal activity in myocardial perfusion imaging studies.

Authors:  Randall C Thompson
Journal:  J Nucl Cardiol       Date:  2008 Mar-Apr       Impact factor: 3.872

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.