Literature DB >> 8949780

Boron neutron capture irradiation: setting up a clinical programme in Nice.

J P Pignol1, P Chauvel, P Paquis, A Courdi, N Iborra-Brassart, M Lonjon, C Lebrun-Frenay, M Frenay, P Grellier, M Chatel, J Hérault, R J Bensadoun, G Milano, F Nepveu, J P Patau, F Demard, N Breteau.   

Abstract

Neutron capture irradiation aims to selectively destroy tumor cells using 10B(n,alpha)7Li nuclear reactions produced within themselves. Following the capture reaction, an alpha particle and a, 7Li ion are emitted. Carrying an energy of 2.79 MeV, they destroy all molecular structures along their path close to 10 microns. These captures, used exclusively with a 'slow' neutron irradiation, provide a neutron capture therapy (BNCT). If they are used in addition to a fast neutron beam irradiation, they provide a neutron capture potentiation (NCP). The Centre Antoine-Lacassagne in Nice is actively involved in the European Demonstration Project for BNCT of grade IV glioblastomas (GBM) after surgical excision and BSH administration. Taking into account the preliminary results obtained in Japan, work on an 'epithermal' neutron target compatible with various cyclotron beams is in progress to facilitate further developments of this technique. For NCP, thermalized neutron yield has been measured in phantoms irradiated in the fast neutron beam of the biomedical cyclotron in Nice. A thermal peak appears after 5 cm depth in the tissues, delayed after the fast neutron peak at 1.8 cm depth. Thus, a physical overdosage of 10% may be obtained if 100 ppm of 10B are assumed in the tissues. Our results using CAL 58 GBM cell line demonstrate a dose modification factor (DMF) of 1.19 when 100 ppm of boric acid are added to the growth medium. Thus for the particles, issued from neutron capture, a biological efficiency at least twice that of fast neutrons can be derived. These results, compared with historical data on fast neutron irradiation of glioblastoma, suggest that a therapeutic window may be obtained for GBM.

Entities:  

Mesh:

Year:  1996        PMID: 8949780     DOI: 10.1016/0924-4212(96)84913-9

Source DB:  PubMed          Journal:  Bull Cancer Radiother        ISSN: 0924-4212


  1 in total

1.  Boron neutron capture enhancement (BNCE) of fast neutron irradiation for glioblastoma: increase of thermal neutron flux with heavy material collimation, a theoretical evaluation.

Authors:  P Paquis; J P Pignol; M Lonjon; N Brassart; A Courdi; P Chauvel; P Grellier; M Chatel
Journal:  J Neurooncol       Date:  1999-01       Impact factor: 4.130

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.