Literature DB >> 8948506

A new reliable chemiluminescence immunoassay (CLIA) for prostaglandin E2 using enhanced luminol as substrate.

W Neupert1, R Oelkers, K Brune, G Geisslinger.   

Abstract

A sensitive and reliable chemiluminescence immunoassay suitable for the quantitative determination of prostaglandin E2 (PGE2) has been developed using 96 well microtiter plates (MTP). The assay is based on a competitive reaction between a highly specific monoclonal anti-PGE2 antibody (mouse), free antigen and solid phase bound antigen. The MTP was first coated with a bovine serum albumin (BSA)-PGE2 conjugate. Then, after preincubating, the anti-PGE2 antibody (Ab) and the analyte were added. The remaining amount of free antibody was captured by the solid phase bound BSA-PGE2 conjugate. The monoclonal antibody captured on the MTP was determined using biotinylated anti-mouse-Ab and a complex of avidin and biotin-labelled horseradish peroxidase (HRP). Substrate for HRP was the cyclic diacyl hydrazide compound luminol, enhanced by p-iodophenol. Photons emitted during the reaction were measured using a photomultiplier tube. The assay has been validated with assay buffer and human plasma over a concentration range of 10-50,000 pg/ml. The lower limit of quantification is 100 pg/ml (2 pg/well) and 150 pg/ml (3 pg/well) for buffer and plasma, respectively. The intra-day coefficients of variation (CV) for the range of 100-50,000 pg/ml are 3.2-8.9% (buffer) and 4.2-17.7% (plasma) and inter-day CV are 2.9-19.8% (buffer) and 3.6-21.2% (plasma). The method can be used for quantification of PGE2 in biological fluids like plasma and suction blister fluid.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8948506     DOI: 10.1016/s0090-6980(96)00103-7

Source DB:  PubMed          Journal:  Prostaglandins        ISSN: 0090-6980


  5 in total

Review 1.  Luminol-based chemiluminescent signals: clinical and non-clinical application and future uses.

Authors:  Parvez Khan; Danish Idrees; Michael A Moxley; John A Corbett; Faizan Ahmad; Guido von Figura; William S Sly; Abdul Waheed; Md Imtaiyaz Hassan
Journal:  Appl Biochem Biotechnol       Date:  2014-04-22       Impact factor: 2.926

2.  Quantitative profiling of oxylipins through comprehensive LC-MS/MS analysis: application in cardiac surgery.

Authors:  Katrin Strassburg; Annemarie M L Huijbrechts; Kirsten A Kortekaas; Jan H Lindeman; Theresa L Pedersen; Adrie Dane; Ruud Berger; Arjan Brenkman; Thomas Hankemeier; John van Duynhoven; Eric Kalkhoven; John W Newman; Rob J Vreeken
Journal:  Anal Bioanal Chem       Date:  2012-07-20       Impact factor: 4.142

3.  Proinflammatory activity of TWEAK on human dermal fibroblasts and synoviocytes: blocking and enhancing effects of anti-TWEAK monoclonal antibodies.

Authors:  Yves Chicheportiche; Rachel Chicheportiche; Irene Sizing; Jeff Thompson; Christopher B Benjamin; Christine Ambrose; Jean-Michel Dayer
Journal:  Arthritis Res       Date:  2001-11-09

4.  An ultrasensitive chemiluminescence biosensor for carcinoembryonic antigen based on autocatalytic enlargement of immunogold nanoprobes.

Authors:  Minjia Hao; Zhanfang Ma
Journal:  Sensors (Basel)       Date:  2012-12-13       Impact factor: 3.576

Review 5.  Methods of the Analysis of Oxylipins in Biological Samples.

Authors:  Ivan Liakh; Alicja Pakiet; Tomasz Sledzinski; Adriana Mika
Journal:  Molecules       Date:  2020-01-15       Impact factor: 4.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.