Literature DB >> 8947903

Evaluation of ion-implanted-silicon detectors for use in intraoperative positron-sensitive probes.

R R Raylman1, R L Wahl.   

Abstract

The continuing development of probes for use with beta (positron and electron) emitting radionuclides may result in more complete excision of tracer-avid tumors. Perhaps one of the most promising radiopharmaceuticals for this task is 18F-labeled-Fluoro-2-Deoxy-D-Glucose (FDG). This positron-emitting agent has been demonstrated to be avidly and rapidly absorbed by many human cancers. We have investigated the use of ion-implanted-silicon detectors in intraoperative positron-sensitive surgical probes for use with FDG. These detectors possess very high positron detection efficiency, while the efficiency for 511 keV photon detection is low. The spatial resolution, as well as positron and annihilation photon detection sensitivity, of an ion-implanted-silicon detector used with 18F was measured at several energy thresholds. In addition, the ability of the device to detect the presence of relatively small amounts of FDG during surgery was evaluated by simulating a surgical field in which some tumor was left intact following lesion excision. The performance of the ion-implanted-silicon detector was compared to the operating characteristics of a positron-sensitive surgical probe which utilizes plastic scintillator. In all areas of performance the ion-implanted-silicon detector proved superior to the plastic scintillator-based probe. At an energy threshold of 14 keV positron sensitivity measured for the ion-implanted-silicon detector was 101.3 cps/kBq, photon sensitivity was 7.4 cps/kBq. In addition, spatial resolution was found to be relatively unaffected by the presence of distant sources of annihilation photon flux. Finally, the detector was demonstrated to be able to localize small amounts of FDG in a simulated tumor bed; indicating that this device has promise as a probe to aid in FDG-guided surgery.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8947903     DOI: 10.1118/1.597751

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  How few cancer cells can be detected by positron emission tomography? A frequent question addressed by an in vitro study.

Authors:  Barbara M Fischer; Minna W B Olsen; Carsten D Ley; Thomas L Klausen; Jann Mortensen; Liselotte Højgaard; Paul E G Kristjansen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-04-13       Impact factor: 9.236

Review 2.  A comprehensive overview of radioguided surgery using gamma detection probe technology.

Authors:  Stephen P Povoski; Ryan L Neff; Cathy M Mojzisik; David M O'Malley; George H Hinkle; Nathan C Hall; Douglas A Murrey; Michael V Knopp; Edward W Martin
Journal:  World J Surg Oncol       Date:  2009-01-27       Impact factor: 2.754

3.  Positron detection for the intraoperative localisation of cancer deposits.

Authors:  Morand Piert; Maria Burian; Günther Meisetschläger; Hubert J Stein; Sibylle Ziegler; Jörg Nährig; Maria Picchio; Andreas Buck; Joerg R Siewert; Markus Schwaiger
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-04-12       Impact factor: 9.236

Review 4.  Nuclear-medicine probes: Where we are and where we are going.

Authors:  Andrea Gonzalez-Montoro; Cesar David Vera-Donoso; Georgios Konstantinou; Pablo Sopena; Manolo Martinez; Juan Bautista Ortiz; Montserrat Carles; Jose Maria Benlloch; Antonio Javier Gonzalez
Journal:  Med Phys       Date:  2022-05-20       Impact factor: 4.506

  4 in total