Literature DB >> 8945663

Formalin fixation strongly influences biomechanical properties of the spine.

H J Wilke1, S Krischak, L E Claes.   

Abstract

As fresh human cadaveric spine specimens for in vitro testing are hard to obtain and carry a potential risk of infection, the possibility of using embalmed spine specimens has been considered. The cross-linking effect of formalin fixation, however, raises uncertainties regarding the biomechanical likeness of preserved specimens. They have been reported to be stiffer, but no quantitative data exist. The purpose of this study was to determine the biomechanical differences between fresh and formalin-fixed spine specimens, using L1-2 motion segments from six 16-week-old calf spines. The range of motion and neutral zone were determined in flexion-/extension, left/right axial rotation, and right/left lateral bleeding. The range of motion decreased in the formalin fixed specimens by as much as 80%, and the neutral zone by as much as 96%. The results of this study therefore imply that, for biomechanical testing, formalin-fixed specimens are not representative of the in vivo conditions.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8945663

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  15 in total

1.  Transmission of force in the lumbosacral spine during backward falls.

Authors:  Carolyn Van Toen; Meena M Sran; Stephen N Robinovitch; Peter A Cripton
Journal:  Spine (Phila Pa 1976)       Date:  2012-04-20       Impact factor: 3.468

2.  Comparison of the efficacy of three isolated gastrocnemius recession procedures in a cadaveric model of gastrocnemius tightness.

Authors:  Kai Rong; Xing-chen Li; Wen-tao Ge; Yang Xu; Xiang-yang Xu
Journal:  Int Orthop       Date:  2015-07-10       Impact factor: 3.075

3.  Locally measured microstructural parameters are better associated with vertebral strength than whole bone density.

Authors:  J Hazrati Marangalou; F Eckstein; V Kuhn; K Ito; M Cataldi; F Taddei; B van Rietbergen
Journal:  Osteoporos Int       Date:  2013-12-04       Impact factor: 4.507

4.  Reproducibility of global three-dimensional motion during manual atlanto-axial rotation mobilization: an in vitro study.

Authors:  Erik Cattrysse; Steven Provyn; Patrick Kool; Jan Pieter Clarys; Peter Van Roy
Journal:  J Man Manip Ther       Date:  2010-03

5.  In vivo baseline measurements of hip joint range of motion in suspensory and nonsuspensory anthropoids.

Authors:  Ashley S Hammond
Journal:  Am J Phys Anthropol       Date:  2013-11-28       Impact factor: 2.868

6.  Biomechanical evaluation of a novel posterior integrated clamp that attaches to an existing posterior instrumentation for use in thoracolumbar revision.

Authors:  Patrick Senatus; Suresh Reddy Chinthakunta; Pedram Vazifeh; Saif Khalil
Journal:  Asian Spine J       Date:  2013-03-06

7.  Osteoporosis imaging: effects of bone preservation on MDCT-based trabecular bone microstructure parameters and finite element models.

Authors:  Thomas Baum; Eduardo Grande Garcia; Rainer Burgkart; Olga Gordijenko; Hans Liebl; Pia M Jungmann; Michael Gruber; Tina Zahel; Ernst J Rummeny; Simone Waldt; Jan S Bauer
Journal:  BMC Med Imaging       Date:  2015-06-26       Impact factor: 1.930

8.  Sequence of the Essex-Lopresti lesion--a high-speed video documentation and kinematic analysis.

Authors:  Kilian Wegmann; Karsten Engel; Klaus J Burkhart; Marc Ebinger; Robert Holz; Gert-Peter Brüggemann; Lars P Müller
Journal:  Acta Orthop       Date:  2014-01-30       Impact factor: 3.717

9.  Biomechanical testing of a unique built-in expandable anterior spinal internal fixation system.

Authors:  Chu-Song Zhou; Yan-Fang Xu; Yu Zhang; Zhong Chen; Hai Lv
Journal:  BMC Musculoskelet Disord       Date:  2014-12-11       Impact factor: 2.362

10.  The impact of bilateral facetectomy on the instantaneous helical axis of the functional thoracic spinal unit T4-5 during axial rotation.

Authors:  Paul Jonathan Roch; Dominik Saul; Nikolai Wüstefeld; Stefan Spiering; Wolfgang Lehmann; Lukas Weiser; Martin Michael Wachowski
Journal:  Int Biomech       Date:  2021-12
View more