Literature DB >> 8945071

Analysis of the p wave in the signal-averaged electrocardiogram: normal values and reproducibility.

M Hofmann1, L Goedel-Meinen, A Beckhoff, K Rehbach, A Schömig.   

Abstract

To apply p wave analysis of the signal-averaged electrocardiogram (SAECG) clinically, the knowledge of normal values and the verification of highly reproducible measurements are essential. In 40 healthy volunteers (ages 23-37 years), an SAECG of the p wave was performed and then repeated after 1 week and 1 month. In addition to Simson analysis (unidirectional and bidirectional filters), the data were filtered with finite impulse response (FIR) and least squares fit (LSQ) filters to obtain a better differentiation between the end of the p wave and QRS onset. All recordings were evaluated by two independent observers, and the following parameters were calculated: the duration of the p wave in the three unfiltered leads; and for the vector magnitude of the three leads x, y, and z: the duration of the p wave and the root mean square voltage of its last 30, 20, and 10 ms. The average p wave duration was significantly different among the various filter techniques: 135 +/- 7 ms (unidirectional); 97 +/- 8 ms (bidirectional); 109 +/- 8.5 ms (FIR); and 126 +/- 10 ms (LSQ) (P = 0.001 for each comparison). There was a good reproducibility of the data analyzed with the Simson method (R = 0.80-0.91). Filtering with the FIR and LSQ leads to a considerably greater variability.

Entities:  

Mesh:

Year:  1996        PMID: 8945071     DOI: 10.1111/j.1540-8159.1996.tb03255.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

1.  Usefulness of P-wave signal averaging to predict atrial fibrillation recurrences after electrical cardioversion.

Authors:  Coralie Blanche; Nam Tran; David Carballo; Fabio Rigamonti; Haran Burri; Marc Zimmermann
Journal:  Ann Noninvasive Electrocardiol       Date:  2014-01-08       Impact factor: 1.468

2.  Predictive value of P-wave signal-averaged electrocardiogram for atrial fibrillation in acute myocardial infarction.

Authors:  Dilek Ciçek; Ahmet Camsari; Hasan Pekdemir; Ahmet Kiykim; Necdet Akkuş; Kerem Sezer; Erdem Diker
Journal:  Ann Noninvasive Electrocardiol       Date:  2003-07       Impact factor: 1.468

3.  Evolution of P-wave morphology in healthy individuals: a 3-year follow-up study.

Authors:  Rasmus Havmöller; Jonas Carlson; Fredrik Holmqvist; Bertil Olsson; Pyotr Platonov
Journal:  Ann Noninvasive Electrocardiol       Date:  2009-07       Impact factor: 1.468

4.  Usefulness of P Wave Duration in Embolic Stroke of Undetermined Source.

Authors:  Moonki Jung; Jin-Seok Kim; Ju Hyeon Song; Jeong-Min Kim; Kwang-Yeol Park; Wang-Soo Lee; Sang Wook Kim; Gregory Yh Lip; Seung Yong Shin
Journal:  J Clin Med       Date:  2020-04-15       Impact factor: 4.241

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.