Literature DB >> 8944982

Platelets are deposited early post-operatively on the leaflet of a mechanical heart valve in sheep without post-operative anticoagulants or antiplatelet agents. A scanning electron microscopic observation of the pyrolytic carbon surface in a mechanical heart valve.

Y Okazaki1, K E Wika, T Matsuyoshi, K Fukamachi, R Kunitomo, K S Tweden, H Harasaki.   

Abstract

Pyrolytic carbon has been used for mechanical heart valves as a thromboresistant, wear resistant, and fatigue resistant material. Thrombosis and thromboembolism, however, remain major mechanical heart valve associated complications and may frequently occur during the early post-operative period. In depth morphologic studies on blood-pyrolytic carbon surface interactions are limited. The purpose of this study was to evaluate the blood compatibility of the pyrolytic carbon surface of St. Jude Medical mechanical heart valves that were implanted in the mitral position of sheep without the administration of post-operative anticoagulants or antiplatelet agents for 2, 4, and 6 weeks. Almost the entire leaflet and orifice ring surfaces were observed by scanning electron microscopy. Although the surfaces appeared clean macroscopically, when observed by electron microscopy, the surface were mottled, mainly by solitary platelets and aggregations. There were only a few leukocytes or red blood cells observed. No fibrin clots were observed on the leaflets. The density of platelet deposition was higher in the vicinity of the pivots and near the edges of the leaflets. The sizes of the platelet aggregations decreased with longer duration. The outer surfaces of the pivot guards were covered by various amounts of deposition composed of platelet aggregations and thrombi. Thus, the administration of antiplatelet agents is recommended during the early post-operative period after mechanical heart valve implantation.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8944982     DOI: 10.1097/00002480-199609000-00089

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

Review 1.  Use of electron microscopy to study platelets and thrombi.

Authors:  Maurizio Tomaiuolo; Rustem I Litvinov; John W Weisel; Timothy J Stalker
Journal:  Platelets       Date:  2020-05-18       Impact factor: 3.862

2.  Early massive thrombosis of a mechanical mitral valve.

Authors:  P Masiello; G Mastrogiovanni; G Santoro; S Iesu; G Di Benedetto
Journal:  Tex Heart Inst J       Date:  1998

3.  Aortic valve replacement in sheep with a novel trileaflet mechanical heart valve prosthesis without anticoagulation.

Authors:  Tim Schaller; Michael Scharfschwerdt; Kathrin Schubert; Cornelia Prinz; Ulrich Lembke; Hans-Hinrich Sievers
Journal:  JTCVS Open       Date:  2021-05-29
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.