Literature DB >> 8943592

Nasotracheal tube placement over the fibreoptic laryngoscope.

S Hughes1, J E Smith.   

Abstract

We have assessed the effectiveness of three tracheal tube rotational movements in assisting nasotracheal tube placement over the fibreoptic laryngoscope. Ninety ASA grade 1 or 2 oral surgery patients undergoing fibreoptic nasotracheal intubation under general anaesthesia were studied. After the fibrescope had been positioned in the trachea, patients were randomly allocated to one of three groups. In group 1, no rotation was used and the tube was advanced towards the trachea in the neutral position. In group 2, the tube was rotated by 90 degrees anticlockwise. In group 3, the tube was rotated by 180 degrees anticlockwise, then rotated back to 90 degrees anticlockwise (overcorrected rotation). If resistance to the advance was encountered, up to two more attempts were allowed, after further rotational manoeuvres had been made, in accordance with a standard, graduated sequence. There were significantly more successful tube placements at the first attempt in groups 2 and 3 (93% and 100% respectively) than in group 1 (63%). It is therefore recommended that 90 degrees anticlockwise or overcorrected 90 degrees anticlockwise tube rotation is used to facilitate nasotracheal tube placement during fibreoptic intubation.

Entities:  

Mesh:

Year:  1996        PMID: 8943592     DOI: 10.1111/j.1365-2044.1996.tb14996.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  4 in total

1.  [Intubation with a tube exchanger on an intubation trainer. Influence of tube tip position on successful intubation].

Authors:  M Kemper; T Haas; S Imach; M Weiss
Journal:  Anaesthesist       Date:  2014-07-02       Impact factor: 1.041

2.  Comparison of two different methods of fiber-optic nasal intubation: conventional method versus facilitated method (NASAL-18).

Authors:  Ali Mohammadzadeh; Mohammad Haghighi; Bahram Naderi; Amanullah Chaudhry; Zahid Hussain Khan; Mohammad R Rasouli; Soheil Saadat
Journal:  Ups J Med Sci       Date:  2011-02-15       Impact factor: 2.384

3.  Comparison of hemodynamic responses to intubation: Flexible fiberoptic bronchoscope versus McCoy laryngoscope in presence of rigid cervical collar simulating cervical immobilization for traumatic cervical spine.

Authors:  Nitesh Gill; Shobha Purohit; Poonam Kalra; Tarun Lall; Avneesh Khare
Journal:  Anesth Essays Res       Date:  2015 Sep-Dec

4.  North Polar Tube Reduces the Risk of Epistaxis during Nasotracheal Intubation: A prospective, Randomized Clinical Trial.

Authors:  Ahmet Seli M Özkan; Sedat Akbas; Erol Toy; Mahmut Durmus
Journal:  Curr Ther Res Clin Exp       Date:  2018-10-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.