Literature DB >> 8942577

Transesophageal echocardiography: an objective tool in defining maximum ventricular response to intravenous fluid therapy.

J D Swenson1, C Harkin, N L Pace, K Astle, P Bailey.   

Abstract

Ventricular preload is an important determinant of cardiac function, which is indirectly measured in the clinical setting by the pulmonary capillary wedge pressure (PCWP). Transesophageal echocardiography (TEE) is rapidly gaining acceptance as a monitor of cardiac function. Although it provides high-resolution images of cardiac structures, clinical assessment of ventricular preload using TEE has been subjective, since quantitative measurements have been difficult to perform in a timely fashion. Automated border detection (ABD) is a new technology used in conjunction with TEE that allows quantitative real-time, two-dimensional measurement of cavity areas. To determine whether enddiastolic area (EDA) measured by ABD can be used to determine an appropriate end point for intravenous fluid administration, nine mongrel dogs were studied. Anesthetized animals were hemorrhaged to achieve a central venous pressure of 0-5 mm Hg. Each animal was then given intravenous fluid (autologous blood followed by hetastarch) until a peak in thermodilution cardiac output (CO) was achieved. Measures of PCWP, EDA, CO, and left ventricular stroke work (LVSW) were obtained after each fluid bolus. Bivariate plots displaying administered volume versus CO, LVSW, and EDA revealed parallel curves for each of these variables with peaks evident at cumulative volumes of 50-55 mL/kg. Multiple regression with mixed model analysis of covariance was performed to determine the significance of EDA in relation to changes in CO and LVSW. Analysis was likewise performed comparing the relationship between PCWP and changes in CO or LVSW. A significant relationship was demonstrated when comparing EDA to changes in CO and LVSW (P = 0.03 and P < 0.0001, respectively). Similar analysis comparing PCWP to changes in CO and LVSW failed to demonstrate a significant relationship (P = 0.54 and P = 0.36, respectively). These data suggest that changes in EDA measured using TEE with ABD are related to trends in cardiac function and can suggest an appropriate end point for intravenous fluid administration as defined by maximum CO and LVSW. PCWP did not demonstrate a significant relationship to changes in CO and LVSW.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8942577     DOI: 10.1097/00000539-199612000-00003

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  9 in total

Review 1.  Transoesophageal echocardiography during liver transplantation.

Authors:  Lesley De Pietri; Federico Mocchegiani; Chiara Leuzzi; Roberto Montalti; Marco Vivarelli; Vanni Agnoletti
Journal:  World J Hepatol       Date:  2015-10-18

2.  Ultrasound Assessment of the Change in Carotid Corrected Flow Time in Fluid Responsiveness in Undifferentiated Shock.

Authors:  Igor Barjaktarevic; William E Toppen; Scott Hu; Elizabeth Aquije Montoya; Stephanie Ong; Russell Buhr; Ian J David; Tisha Wang; Talayeh Rezayat; Steven Y Chang; David Elashoff; Daniela Markovic; David Berlin; Maxime Cannesson
Journal:  Crit Care Med       Date:  2018-11       Impact factor: 7.598

3.  Position dependent right ventricular dysfunction caused by a giant right coronary artery aneurysm.

Authors:  Bruno Mora; Bernhard Urbanek; Christian Loewe; Michael Grimm; Martin Dworschak
Journal:  Wien Klin Wochenschr       Date:  2011-01-21       Impact factor: 1.704

Review 4.  Haemodynamic monitoring in acute heart failure.

Authors:  Maurizio Cecconi; Toby E Reynolds; Nawaf Al-Subaie; Andrew Rhodes
Journal:  Heart Fail Rev       Date:  2007-06       Impact factor: 4.214

5.  Fluid responsiveness and right ventricular function in cardiac surgical patients. A multicenter study.

Authors:  M Ranucci; A Pazzaglia; L Tritapepe; F Guarracino; M Lupo; V Salandin; P Del Sarto; A Condemi; R Campodonico; G Laudani; D Pittarello; L Belloni
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2009

Review 6.  Sepsis-induced cardiomyopathy.

Authors:  Francisco J Romero-Bermejo; Manuel Ruiz-Bailen; Julian Gil-Cebrian; Maria J Huertos-Ranchal
Journal:  Curr Cardiol Rev       Date:  2011-08

7.  Echocardiography practice, training and accreditation in the intensive care: document for the World Interactive Network Focused on Critical Ultrasound (WINFOCUS).

Authors:  Susanna Price; Gabriele Via; Erik Sloth; Fabio Guarracino; Raoul Breitkreutz; Emanuele Catena; Daniel Talmor
Journal:  Cardiovasc Ultrasound       Date:  2008-10-06       Impact factor: 2.062

8.  Sonographic Evaluation of Internal Jugular Vein Diameter and Cross-sectional Area Measurements in Correlation with Left Ventricular End Diastolic Area as a Tool for Perioperative Assessment of Volume Status in Pediatric Patients Undergoing Cardiac Surgery.

Authors:  Wafaa Mohamed Elsadek; Amal Hanfy Abo Elaela; Heba Mohamed Nassar; Mohamed Maher Kamel; Ahmed Abdelaziz Mohamed; Hassan Mohamed Ali
Journal:  Anesth Essays Res       Date:  2017 Apr-Jun

9.  The Utility of 3D Left Atrial Volume and Mitral Flow Velocities as Guides for Acute Volume Resuscitation.

Authors:  Claudia M Santosa; David D Rose; Neal W Fleming
Journal:  Biomed Res Int       Date:  2015-07-07       Impact factor: 3.411

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.