Literature DB >> 8942330

Use of a mechanical simulator for training in applying cricoid pressure.

N Ashurst1, C C Rout, D A Rocke, E Gouws.   

Abstract

Using an airway management training model, we have assessed anaesthesia personnel in their use of correct cricoid force and ability to retain this skill after a short training programme. A perspex device, working on a hydraulic principle, was used to measure cricoid pressure when applied to the model. After initial assessment at two levels of cricoid force (20 and 40 N), participants undertook additional training on 3 consecutive days. Thereafter, available participants underwent reassessment at 14-21 days. Forty-nine anaesthetic assistants and anaesthetists underwent initial assessment and 18 completed the full training and reassessment. Untrained, the majority (63%) of participants applied inadequate cricoid force with a wide variation (mean 16.8 (SD 9.3) (range 4.5-43.0) at 20 N and 32.9 (13.3) (14.9-74) at 40 N). After a single training session there was a marked improvement in application of cricoid force. Two additional training sessions did not provide further improvement. After 14-21 days the ability of participants to apply correct cricoid force was retained by 72% of subjects. Those who applied inadequate cricoid force initially were more likely to do so even after training. Most subjects applied too great a cricoid force in the first 5 s of application followed by a progressive loss of force during the next 20 s. This trend improved after training. We conclude that the majority of untrained personnel apply inadequate cricoid force, placing patients at risk of aspiration of gastric contents. While a simple training programme improved application of cricoid force, retained for up to 3 weeks, there was often a substantial decrease in the force applied to the cricoid during a single application, even after training.

Entities:  

Mesh:

Year:  1996        PMID: 8942330     DOI: 10.1093/bja/77.4.468

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  3 in total

1.  Pressure to change: a low-cost anatomically accurate cricoid pressure simulator for just-in-time training.

Authors:  Mark Parson; Nathaniel Duke
Journal:  BMJ Simul Technol Enhanc Learn       Date:  2019-12-24

2.  Effectiveness of cricoid pressure in preventing gastric aspiration during rapid sequence intubation in the emergency department: study protocol for a randomised controlled trial.

Authors:  Christopher E Trethewy; Julie M Burrows; Don Clausen; Steven R Doherty
Journal:  Trials       Date:  2012-02-16       Impact factor: 2.279

3.  Sellick maneuver assisted real-time to achieve target force range in simulated environment-A prospective observational cross-sectional study on manikin.

Authors:  Hwan Ing Hee; Chiong Ling Wong; Olivia Wijeweera; Rehena Sultana; Ban Leong Sng
Journal:  PLoS One       Date:  2020-02-11       Impact factor: 3.240

  3 in total