Literature DB >> 8942157

Measurement of pressure walking in footwear used in leprosy.

J A Birke1, J G Foto, S Deepak, J Watson.   

Abstract

Pressure measurements were made on 10 leprosy patients while walking barefoot and while using 6 sample shoes. The sample shoes, which represented footwear currently used worldwide in leprosy programmes, included: 1, a USA extradepth shoe without insole; 2, a USA extradepth shoe with insole; 3, a Chinese tennis shoe; 4, a Mozambique sandal; 5, a Bombay sandal; 6, a Bombay sandal with rigid sole; and 7, the patients' prescribed footwear. Peak pressure was significantly lower while walking in all footwear, except with the extradepth shoe without an insole, when compared to barefoot walking. Peak pressure was significantly lower walking in the Bombay sandals, the Chinese tennis shoe, the extradepth shoe with an insert and the patients' prescribed shoe when compared to the extradepth shoe without an insert. Regression analysis showed a significant inverse relationship between pressure and insole thickness (P < 0.001, R2 = 0.17).

Entities:  

Mesh:

Year:  1994        PMID: 8942157     DOI: 10.5935/0305-7518.19940026

Source DB:  PubMed          Journal:  Lepr Rev        ISSN: 0305-7518            Impact factor:   0.537


  4 in total

1.  Dressing plantar wounds with foam dressings, is it too much pressure?

Authors:  Ryan Scott Causby; M Pod; Sara Jones
Journal:  Diabet Foot Ankle       Date:  2011-11-04

2.  Plantar ulcer occurrence among leprosy patients in Northern Nigeria: A study of contributing factors.

Authors:  Gidado Mustapha; Joshua Olusegun Obasanya; Clement Adesigbe; Kuye Joseph; Chukwueme Nkemdilim; Mansur Kabir; Tahir Dahiru
Journal:  Ann Afr Med       Date:  2019 Jan-Mar

Review 3.  Relationship between Plantar Pressure and Sensory Disturbance in Patients with Hansen's Disease-Preliminary Research and Review of the Literature.

Authors:  Syoichi Tashiro; Naoki Gotou; Yuki Oku; Takahiro Sugano; Takuya Nakamura; Hiromi Suzuki; Nao Otomo; Shin Yamada; Tetsuya Tsuji; Yutaka Asato; Norihisa Ishii
Journal:  Sensors (Basel)       Date:  2020-12-06       Impact factor: 3.576

4.  Design feature combinations effects of running shoe on plantar pressure during heel landing: A finite element analysis with Taguchi optimization approach.

Authors:  Zihan Yang; Chuyi Cui; Xianglin Wan; Zhiyi Zheng; Songhua Yan; Hui Liu; Feng Qu; Kuan Zhang
Journal:  Front Bioeng Biotechnol       Date:  2022-09-13
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.