Literature DB >> 8941698

Electromyographic evaluation of the spared serratus anterior after postero-lateral thoracotomy.

P Carbognani1, L Spaggiari, M Rusca, G Pavesi, L Cattelani, A Romani, P Solli, P Bobbio.   

Abstract

Postero-lateral thoracotomy is the standard access in thoracic surgery, and can be carried out dividing or preserving the serratus anterior muscle. This last method, besides its advantages, is still a matter of discussion, in fact traction has been claimed to cause severe muscular damage equal to section. We have studied 20 patients (16 males and 4 females, mean age 63 years), who underwent postero-lateral thoracotomy sparing the serratus anterior, after 6 months from surgery, both clinically and by means of electromyography (EMG), to evaluate the functional status of the spared muscles. In 4 cases (20%) there wasn't any neurogenic damage nor clinical evidence of winging scapula; 3 cases (15%) had medium neurogenic damage. The remaining 13 (65%) cases had a medium neurogenic damage and only one patient showed a winging scapula, neverthless being able to lift the arm to shoulder level. Our data confirmed that retraction during surgery does not damage the serratus anterior, leaving a functionally valid muscle.

Entities:  

Mesh:

Year:  1996        PMID: 8941698

Source DB:  PubMed          Journal:  J Cardiovasc Surg (Torino)        ISSN: 0021-9509            Impact factor:   1.888


  1 in total

1.  Winged scapula following axillary thoracotomy with long thoracic nerve preservation.

Authors:  Tomomi Isono; Shigeshi Mori; Hidenori Kusumoto; Hiroyuki Shiono
Journal:  BMJ Case Rep       Date:  2020-02-19
  1 in total