Literature DB >> 8939150

Natural rubber latex skin testing reagents: safety and diagnostic accuracy of nonammoniated latex, ammoniated latex, and latex rubber glove extracts.

R G Hamilton1, N F Adkinson.   

Abstract

BACKGROUND: Nonammoniated latex, ammoniated latex, and rubber glove extracts are the only sources of natural rubber (Hevea brasiliensis) latex that have potential for use as skin testing reagents in the diagnosis of latex allergy. Their diagnostic sensitivity and specificity as skin test reagents are unknown.
OBJECTIVE: We conducted a phase 1/2 clinical study to examine the safety and diagnostic accuracy (sensitivity and specificity) of nonammoniated latex, ammoniated latex, and rubber glove extracts as skin test extracts to identify the most efficacious source material for future skin test reagent development.
METHODS: Twenty-four adults not allergic to latex, 19 adults with hand dermatitis or pruritus, and 59 adults with a latex allergy were identified by clinical history. All provided blood and then received puncture skin tests and intradermal skin tests with nonammoniated latex, ammoniated latex, and rubber glove extracts from Malaysian H. brasiliensis latex by use of sequential titration. A glove provocation test and IgE anti-latex RAST were used to clarify positive history-negative skin test response and negative history-positive skin test response mismatches.
RESULTS: All three extracts were biologically safe and sterile. After normalization to 1 mg/ml of total protein, all three extracts produced equivalent diagnostic sensitivity and specificity in puncture skin tests and intradermal skin tests at various extract concentrations. Optimal diagnostic accuracy was safely achieved at 100 micrograms/ml for intradermal skin tests (e.g., nonammoniated latex: puncture skin test sensitivity 96%, specificity 100%; intradermal skin test sensitivity 93%, specificity 96%). The presence of IgE antibody in skin was highly correlated with IgE anti-latex in serum (nonammoniated latex: r = 0.98, p < 0.001; ammoniated latex: r = 0.94, p < 0.001; rubber glove extract: r = 0.96, p < 0.001). All five available subjects with a positive history, negative skin test response, and absence of IgE antibody in serum had a negative glove provocation test response, indicating no clinical evidence of latex allergy. No systemic or large local allergic reactions were observed with puncture skin tests or intradermal skin tests.
CONCLUSIONS: Equivalent diagnostic sensitivity and specificity were observed with the nonammoniated latex, ammoniated latex, and rubber glove extract skin test reagents after normalization for total protein; nonammoniated latex may be considered the reagent of choice on the basis of practical quality control and reproducibility considerations.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8939150     DOI: 10.1016/s0091-6749(96)80003-0

Source DB:  PubMed          Journal:  J Allergy Clin Immunol        ISSN: 0091-6749            Impact factor:   10.793


  5 in total

1.  Latex allergy--the latest insights.

Authors:  K Kim
Journal:  West J Med       Date:  1997-11

2.  Receiver operating characteristics analyses of Food and Drug Administration-cleared serological assays for natural rubber latex-specific immunoglobulin E antibody.

Authors:  R E Biagini; E F Krieg; L E Pinkerton; R G Hamilton
Journal:  Clin Diagn Lab Immunol       Date:  2001-11

3.  Induction of mucosal tolerance with recombinant Hev b 1 and recombinant Hev b 3 for prevention of latex allergy in BALB/c mice.

Authors:  K Hufnagl; B Wagner; B Winkler; K Baier; R Hochreiter; J Thalhamer; D Kraft; O Scheiner; H Breiteneder; U Wiedermann
Journal:  Clin Exp Immunol       Date:  2003-08       Impact factor: 4.330

4.  Latex allergies: a review of recognition, evaluation, management, prevention, education, and alternative product use.

Authors:  Helen M Binkley; Traci Schroyer; Jennifer Catalfano
Journal:  J Athl Train       Date:  2003-04       Impact factor: 2.860

5.  Latex allergy and occupational asthma in health care workers: adverse outcomes.

Authors:  Sania Amr; William A Suk
Journal:  Environ Health Perspect       Date:  2004-03       Impact factor: 9.031

  5 in total