Literature DB >> 8938040

Monte Carlo and experimental evaluation of accuracy and noise properties of two scatter correction methods for SPECT.

Y Narita1, S Eberl, H Iida, B F Hutton, M Braun, T Nakamura, G Bautovich.   

Abstract

Scatter correction is a prerequisite for quantitative SPECT, but potentially increases noise. Monte Carlo simulations (EGS4) and physical phantom measurements were used to compare accuracy and noise properties of two scatter correction techniques: the triple-energy window (TEW), and the transmission dependent convolution subtraction (TDCS) techniques. Two scatter functions were investigated for TDCS: (i) the originally proposed mono-exponential function (TDCSmono) and (ii) an exponential plus Gaussian scatter function (TDCSGauss) demonstrated to be superior from our Monte Carlo simulations. Signal to noise ratio (S/N) and accuracy were investigated in cylindrical phantoms and a chest phantom. Results from each method were compared to the true primary counts (simulations), or known activity concentrations (phantom studies). 99mTc was used in all cases. The optimized TDCS(Gauss) method overall performed best, with an accuracy of better than 4% for all simulations and physical phantom studies. Maximum errors for TEW and TDCS(mono) of -30 and -22%, respectively, were observed in the heart chamber of the simulated chest phantom. TEW had the worst S/N ratio of the three techniques. The S/N ratios of the two TDCS methods were similar and only slightly lower than those of simulated true primary data. Thus, accurate quantitation can be obtained with TDCS(Gauss), with a relatively small reduction in S/N ratio.

Mesh:

Substances:

Year:  1996        PMID: 8938040     DOI: 10.1088/0031-9155/41/11/017

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

1.  Characterization of scatter and penetration using Monte Carlo simulation in 131I imaging.

Authors:  Y K Dewaraja; M Ljungberg; K F Koral
Journal:  J Nucl Med       Date:  2000-01       Impact factor: 10.057

2.  Effect of scatter correction on the compartmental measurement of striatal and extrastriatal dopamine D2 receptors using [123I]epidepride SPET.

Authors:  Masahiro Fujita; Andrea Varrone; Kyeong Min Kim; Hiroshi Watabe; Sami S Zoghbi; Nicholas Seneca; Dnyanesh Tipre; John P Seibyl; Robert B Innis; Hidehiro Iida
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-01-17       Impact factor: 9.236

Review 3.  Scatter modelling and compensation in emission tomography.

Authors:  Habib Zaidi; Kenneth F Koral
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-31       Impact factor: 9.236

4.  Development of a practical image-based scatter correction method for brain perfusion SPECT: comparison with the TEW method.

Authors:  Miho Shidahara; Hiroshi Watabe; Kyeong Min Kim; Takashi Kato; Shoji Kawatsu; Rikio Kato; Kumiko Yoshimura; Hidehiro Iida; Kengo Ito
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-05-28       Impact factor: 9.236

5.  Quantitative SPECT/CT: SPECT joins PET as a quantitative imaging modality.

Authors:  Dale L Bailey; Kathy P Willowson
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-09-14       Impact factor: 9.236

Review 6.  Quantitative assessment of regional myocardial blood flow with thallium-201 and SPECT.

Authors:  H Iida; S Eberl
Journal:  J Nucl Cardiol       Date:  1998 May-Jun       Impact factor: 5.952

7.  Transmission-based scatter correction of 180 degrees myocardial single-photon emission tomographic studies.

Authors:  B F Hutton; A Osiecki; S R Meikle
Journal:  Eur J Nucl Med       Date:  1996-10

8.  MIRD pamphlet No. 23: quantitative SPECT for patient-specific 3-dimensional dosimetry in internal radionuclide therapy.

Authors:  Yuni K Dewaraja; Eric C Frey; George Sgouros; A Bertrand Brill; Peter Roberson; Pat B Zanzonico; Michael Ljungberg
Journal:  J Nucl Med       Date:  2012-06-28       Impact factor: 10.057

9.  Verification of phantom accuracy using a Monte Carlo simulation: bone scintigraphy chest phantom.

Authors:  Toshimune Ito; Hirotatsu Tsuchikame; Hajime Ichikawa; Masahisa Onoguchi; Koichi Okuda; Takayuki Shibutani; Noriyo Yokotsuka; Hiroshi Tomizawa
Journal:  Radiol Phys Technol       Date:  2021-07-24

10.  Absolute quantitation of myocardial blood flow with (201)Tl and dynamic SPECT in canine: optimisation and validation of kinetic modelling.

Authors:  Hidehiro Iida; Stefan Eberl; Kyeong-Min Kim; Yoshikazu Tamura; Yukihiko Ono; Mayumi Nakazawa; Antti Sohlberg; Tsutomu Zeniya; Takuya Hayashi; Hiroshi Watabe
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-01-15       Impact factor: 9.236

View more