Literature DB >> 8937802

Pocket-sized spirometer for monitoring bronchial challenge procedures.

H Keskinen1, P Piirilä, H Nordman, M Nurminen.   

Abstract

Diagnosis of occupational asthma is verified by inhalation challenge testing when frequent monitoring of peak expiratory flow (PEF) or forced expiratory volume in 1 s (FEV1) is needed. FEV1 measurements also allow frequent monitoring of changes in small airways. For the follow-up of lung function of suspected occupational asthma, a reliable, personal and mobile device is needed. We studied the accuracy of a pocket-sized spirometer, Micro Plus Spirometer (MP), compared with our former combination of two devices, i.e. the values of forced expiratory volume in 1 s (FEV1) with those measured with the Vitalograph bellow spirometer (V); and the peak expiratory flow (PEF) values with the values obtained with a Wright PEF meter (W). In healthy control subjects, the values of FEV1 obtained with Micro Plus correspond well to those obtained using a bellow spirometer (R = 0.97) and the mean difference (MP-V) was -0.06 1 irrespective of the mean FEV1 value. W gives smaller PEF values than the MP; the mean difference in PEF (MP-W) was 44 1 min-1, but the values increased linearly with increasing flow. The poor relation between PEF values might be based on the low reliability of the Wright device. In patient follow-up, the FEV1 values measured with MP and V showed a good correlation (R = 0.99). The PEF values in patients increase linearly measured with W vs. MP with increasing flow values. In conclusion, we found the pocket-sized spirometer a handy and useful device for monitoring bronchial challenge procedures in patients with suspected occupational asthma. The number of exhalations during the challenge test follow-up is lessened when FEV1 and peak expiratory flow (PEF) can be measured simultaneously.

Entities:  

Mesh:

Year:  1996        PMID: 8937802     DOI: 10.1111/j.1475-097x.1996.tb00740.x

Source DB:  PubMed          Journal:  Clin Physiol        ISSN: 0144-5979


  3 in total

1.  New-onset adult asthma in relation to damp and moldy workplaces.

Authors:  Kirsi Karvala; Elina Toskala; Ritva Luukkonen; Sanna Lappalainen; Jukka Uitti; Henrik Nordman
Journal:  Int Arch Occup Environ Health       Date:  2010-02-03       Impact factor: 3.015

2.  Second-hand smoke and chronic bronchitis in Taiwanese women: a health-care based study.

Authors:  Chia-Fang Wu; Nan-Hsiung Feng; Inn-Wen Chong; Kuen-Yuh Wu; Chien-Hung Lee; Jhi-Jhu Hwang; Chia-Tsuan Huang; Chung-Ying Lee; Shao-Ting Chou; David C Christiani; Ming-Tsang Wu
Journal:  BMC Public Health       Date:  2010-01-28       Impact factor: 3.295

3.  Effects of pelvic tilt angles and forced vital capacity in healthy individuals.

Authors:  Young-In Hwang; Ki-Song Kim
Journal:  J Phys Ther Sci       Date:  2018-01-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.