Literature DB >> 8933455

Surgical exposure of the dorsal proximal third of the radius: how vulnerable is the posterior interosseous nerve?

R J Strauch1, M P Rosenwasser, P A Glazer.   

Abstract

This study determined the distance between the posterior interosseous nerve and the bicipital tuberosity of the radius in cadavers. Both elbows of 15 preserved cadavers were dissected (eight male cadavers, seven female cadavers). The most prominent point of the radial tuberosity was located, and the shortest distance from this area to the posterior interosseous nerve was measured. The average distance was 2.3 cm (range 1.8 to 3.2 cm); the intracadaver (right vs left) variation was 1.3 mm. The tuberosity to nerve distance was unaffected by forearm rotation. Palpation of the prominence of the radial tuberosity is a reliable guide to the position of the posterior interosseous nerve in dorsal approaches to the proximal forearm.

Mesh:

Year:  1996        PMID: 8933455     DOI: 10.1016/s1058-2746(96)80064-4

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  6 in total

1.  Variations in the anatomic relations of the posterior interosseous nerve associated with proximal forearm trauma.

Authors:  Ryan P Calfee; Joyce M Wilson; Ambrose H W Wong
Journal:  J Bone Joint Surg Am       Date:  2011-01-05       Impact factor: 5.284

2.  Safe zone for the posterior interosseous nerve with regard to the lateral and posterior approaches to the proximal radius.

Authors:  Gloria Maria Hohenberger; Angelika Maria Schwarz; Marco Johannes Maier; Peter Grechenig; Jan Dauwe; Christoph Grechenig; Renate Krassnig; Axel Gänsslen; Andreas Heinrich Weiglein
Journal:  Surg Radiol Anat       Date:  2018-04-04       Impact factor: 1.246

Review 3.  Complications of radial head prostheses.

Authors:  Stéphanie Delclaux; Julie Lebon; Amélie Faraud; Julien Toulemonde; Nicolas Bonnevialle; Bertrand Coulet; Pierre Mansat
Journal:  Int Orthop       Date:  2015-02-06       Impact factor: 3.075

4.  Distance of the Posterior Interosseous Nerve from the Radial Head during Elbow Arthroscopy: An Anatomical Study.

Authors:  Paolo Arrigoni; Davide Cucchi; Enrico Guerra; Alessandro Marinelli; Alessandra Menon; Pietro Simone Randelli; Luigi Adriano Pederzini
Journal:  Joints       Date:  2017-08-04

5.  Posterior interosseous nerve localization within the proximal forearm - a patient normalized parameter.

Authors:  Srinath Kamineni; Crystal R Norgren; Evan M Davidson; Ellora P Kamineni; Andrew S Deane
Journal:  World J Orthop       Date:  2017-04-18

6.  Fingerbreadths Rule in Determining the Safe Zone of the Radial Nerve and Posterior Interosseous Nerve for a Lateral Elbow Approach: An Anatomic Study.

Authors:  Juan P Simone; Philipp N Streubel; Joaquín Sánchez-Sotelo; Scott P Steinmann; Julie E Adams
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2019-02-20
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.