A newly-designed shape-memory coil stent for esophageal stricture: a preliminary report.

S Tamura1, M Hirao, H Shiozaki, M Inoue, T Hashimoto, S Hori, I Ohkata, H Asano, M Monden.   

Abstract

A newly designed coil esophageal endoprosthesis was developed using a thermal shape-memory titanium-nickel alloy. The major advantages of this stent lie in (a) its small diameter while in its compressed state in ice water and (b) the large lumen which is achieved once it has been warmed to body temperature. The technical feasibility and tissue compatibility of this stent were tested on four beagle dogs: two with an anastomotic stricture and two with a stenosis induced by the injection of monoethanolamine oleate. The teflon-coated stent was inserted under fluoroscopy and removed 4 weeks after implantation. No signs of esophageal reobstruction were observed in any of the animals after implantation or extraction of the stent, although the dog which had received the first stent without teflon coating developed obstruction caused by granulation tissue. Our preliminary experience strongly suggests that the shape-memory alloy stent with teflon coating may be used in the endoscopic treatment of anastomotic stenosis after esophagectomy, as well as of esophageal obstruction caused by carcinoma.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8931232     DOI: 10.1007/bf00311803

Source DB:  PubMed          Journal:  Surg Today        ISSN: 0941-1291            Impact factor:   2.549


  10 in total

1.  Malignant esophageal strictures: treatment with a self-expanding nitinol stent.

Authors:  W Cwikiel; H Stridbeck; K G Tranberg; C S von Holstein; G Hambraeus; R Lillo-Gil; R Willén
Journal:  Radiology       Date:  1993-06       Impact factor: 11.105

2.  A new self-expandable, nickel-titanium coil stent for esophageal obstruction: a preliminary report.

Authors:  E Goldin; M Beyar; T Safra; O Globerman; I Craciun; D Wengrower; A Fich
Journal:  Gastrointest Endosc       Date:  1994 Jan-Feb       Impact factor: 9.427

3.  A new intratracheal stent made from nitinol, an alloy with "shape memory effect".

Authors:  I Vinograd; B Klin; T Brosh; M Weinberg; Y Flomenblit; Z Nevo
Journal:  J Thorac Cardiovasc Surg       Date:  1994-05       Impact factor: 5.209

4.  Palliative treatment of obstructing esophagogastric malignancy by endoscopic positioning of a plastic prosthesis.

Authors:  F C den Hartog Jager; J F Bartelsman; G N Tytgat
Journal:  Gastroenterology       Date:  1979-11       Impact factor: 22.682

5.  Metallic self-expanding stent application in the upper gastrointestinal tract: caveats and concerns.

Authors:  R A Kozarek; T J Ball; D J Patterson
Journal:  Gastrointest Endosc       Date:  1992 Jan-Feb       Impact factor: 9.427

6.  Titanium-nickel intravascular endoprosthesis: a 2-year study in dogs.

Authors:  C S Sutton; T Oku; H Harasaki; H E Kambic; Y Sugita; S Murabayashi; E Shirey; Y Nosè
Journal:  AJR Am J Roentgenol       Date:  1988-09       Impact factor: 3.959

7.  Incidence and management of benign anastomotic stricture after cervical oesophagogastrostomy.

Authors:  J P Pierie; P W de Graaf; H Poen; I van der Tweel; H Obertop
Journal:  Br J Surg       Date:  1993-04       Impact factor: 6.939

8.  Oesophageal stricture and dysphagia after endoscopic sclerotherapy for bleeding varices.

Authors:  T Sørensen; F Burcharth; M L Pedersen; F Findahl
Journal:  Gut       Date:  1984-05       Impact factor: 23.059

Review 9.  Silicone-covered self-expanding metallic stents for the palliation of malignant esophageal obstruction and esophagorespiratory fistulas: experience in 32 patients and a review of the literature.

Authors:  W C Wu; R M Katon; R R Saxon; R E Barton; B T Uchida; F S Keller; J Rösch
Journal:  Gastrointest Endosc       Date:  1994 Jan-Feb       Impact factor: 9.427

10.  Self-expandable nitinol stent for the management of biliary obstruction: long-term clinical results.

Authors:  M Bezzi; F Orsi; F M Salvatori; F Maccioni; P Rossi
Journal:  J Vasc Interv Radiol       Date:  1994 Mar-Apr       Impact factor: 3.464

  10 in total