Literature DB >> 8931230

Thrombotic obstruction of a reinforced ringed expanded polytetrafluoroethylene graft caused by formation of a pseudoaneurysm at a nonanastomotic site: report of a case.

K Akiyama1, J Hirota, Y Shiina, A Ohkado, S Ohsawa, Y Kainuma.   

Abstract

We report herein the case of a 72-year-old man in whom a nonanastomotic pseudoaneurysm arose from a reinforced ringed expanded polytetrafluoroethylene (EPTFE) graft (Gore-Tex, Flagstaff, AZ, USA) following an axillobifemoral bypass. The pseudoaneurysm developed 2 years after graft insertion and induced graft thrombosis. The development of the pseudoaneurysm can be attributed to the fact that his axillobifemoral bypass graft was so short it deformed the proximal anastomosis, and the graft was subcutaneously tunneled onto the major pectoral muscle. These technical errors placed the graft under too much tension in the longitudinal direction, which resulted in graft disruption and pseudoaneurysmal formation, followed by thrombosis of the axillary artery. Moreover, the possibility of direct trauma at the time of insertion cannot be substantiated. Although the very poor compliance and design of the externally supported ring could not tolerate stretch deformity in the Gore-Tex graft, only one other case of a nonanastomotic pseudoaneurysm has ever been reported.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8931230     DOI: 10.1007/bf00311801

Source DB:  PubMed          Journal:  Surg Today        ISSN: 0941-1291            Impact factor:   2.549


  9 in total

1.  Aneurysm formation in expanded polytetrafluoroethylene prostheses.

Authors:  C D Campbell; D H Brooks; M W Webster; R P Bondi; J C Lloyd; M F Hynes; H T Bahnson
Journal:  Surgery       Date:  1976-05       Impact factor: 3.982

2.  Clinical significance of aortic graft dilation.

Authors:  R M Blumenberg; M L Gelfand; E A Barton; C A Bowers; D A Gittleman
Journal:  J Vasc Surg       Date:  1991-08       Impact factor: 4.268

3.  Fifteen year experience with subcutaneous bypass grafts for lower extremity ischemia.

Authors:  J Eugene; J Goldstone; W S Moore
Journal:  Ann Surg       Date:  1977-08       Impact factor: 12.969

4.  Is axillo-bilateral femoral graft an effective substitute for aortic-bilateral iliac/femoral graft?: an analysis of ten years experience.

Authors:  W C Johnson; F W Logerfo; R W Vollman; J D Corson; E T O'Hara; J A Mannick; D C Nabseth
Journal:  Ann Surg       Date:  1977-08       Impact factor: 12.969

5.  Disruption of the proximal anastomosis of axillobifemoral grafts: two case reports.

Authors:  L P Sullivan; P G Davidson; J A D'Anna; N Sithian
Journal:  J Vasc Surg       Date:  1989-08       Impact factor: 4.268

6.  The late results of axillofemoral grafts.

Authors:  J A Mannick; L E Williams; D C Nabseth
Journal:  Surgery       Date:  1970-12       Impact factor: 3.982

7.  Optimal proximal anastomosis/tunnel for axillofemoral grafts.

Authors:  T J Bunt; W Moore
Journal:  J Vasc Surg       Date:  1986-04       Impact factor: 4.268

8.  Polytetrafluoroethylene graft aneurysms: a report of five aneurysms.

Authors:  L L Mohr; L L Smith
Journal:  Arch Surg       Date:  1980-12

9.  Nonanastomotic pseudoaneurysm of expanded polytetrafluoroethylene axillofemoral bypass graft.

Authors:  D Piazza; F M Ameli; H P von Schroeder; A Lossing
Journal:  J Vasc Surg       Date:  1993-04       Impact factor: 4.268

  9 in total
  4 in total

1.  Clinical analysis of non-anastomotic aneurysms of implanted prosthetic grafts.

Authors:  Satoshi Yamamoto; Katsuyuki Hoshina; Hideo Kimura; Hiroyuki Okamoto; Kunihiro Shigematsu; Tetsuro Miyata; Toshiaki Watanabe
Journal:  Surg Today       Date:  2014-04-03       Impact factor: 2.549

2.  Traumatic nonanastomotic axilloprofundal PTFE-bypass rupture: a case report.

Authors:  Borna K Barth; Fabian Hässler; Oliver Graubitz
Journal:  Radiol Case Rep       Date:  2016-12-22

3.  Non-Anastomotic Complete ePTFE Axillobifemoral Bypass Disruption and Thrombosis Following Shoulder Dislocation.

Authors:  Benoît Lucereau; Arielle Bellissard; Frédéric Beck; Delphine Dion; Frédéric Heim; Nabil Chakfe; Anne Lejay
Journal:  EJVES Short Rep       Date:  2019-07-30

4.  A Unique Case of an Expanded Polytetrafluoroethylene Graft Rupture 14 Years after Abdominal Aortic Aneurysm Open Repair Managed with Placement of a Thoracic Endograft.

Authors:  Loukia Alexopoulou-Prounia; Stavros K Kakkos; Chrysanthi P Papageorgopoulou; Konstantinos Katsanos; Peter Zampakis; Polyzois Tsantrizos; Ioannis Ntouvas
Journal:  Aorta (Stamford)       Date:  2021-12-28
  4 in total