Literature DB >> 8926564

Whole saliva dried on filter paper or diagnosis of HIV-1 infection by detection of antibody IgG to HIV-1 with ultrasensitive enzyme immunoassay using recombinant reverse transcriptase as antigen.

S Ishikawa1, S Hashida, K Hashinaka, K Hirota, M Kojima, A Saito, A Takamizawa, H Shinagawa, S Oka, K Shimada, E Ishikawa.   

Abstract

Whole saliva samples collected from HIV-1 seropositive subjects by simple spitting without using any devices were dried on filter paper strips, from which filter paper discs of 3-mm diameter were punched out. The eluates of the discs were subjected to the immune complex transfer enzyme immunoassay for antibody IgG to HIV-1 using recombinant reverse transcriptase of HIV-1 as antigen and a two-site enzyme immunoassay for whole IgG. The signals for antibody IgG to HIV-1 and the amounts of whole IgG obtained with one disc per assay tube were 126-290% of those obtained with 1 microliter of whole saliva samples, provided that filter paper strips were treated with nonspecific rabbit serum prior to drying whole saliva samples and that filter paper discs were tested within a few days after drying whole saliva samples. From these results, diagnosis of HIV-1 infection was indicated to be possible with whole saliva samples dried on filter papers, since the diagnosis was previously shown to be possible with 1 microliter of whole saliva samples. The test for HIV-1 infection with whole saliva samples dried on filter papers was suggested to be useful for various purposes.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8926564     DOI: 10.1002/(SICI)1098-2825(1996)10:1<35::AID-JCLA6>3.0.CO;2-K

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  12 in total

1.  Rapid formation of the immune complexes on solid phase in the immune complex transfer enzyme immunoassays for HIV-1 p24 antigen and antibody IgGs to HIV-1.

Authors:  S Ishikawa; S Hashida; K Hashinaka; A Adachi; S Oka; E Ishikawa
Journal:  J Clin Lab Anal       Date:  1998       Impact factor: 2.352

2.  Rapid and ultrasensitive enzyme immunoassay (thin aqueous layer immune complex transfer enzyme immunoassay) for HIV-1 p24 antigen.

Authors:  S Ishikawa; S Hashida; K Hashinaka; E Ishikawa
Journal:  J Clin Lab Anal       Date:  1998       Impact factor: 2.352

3.  Immune complex transfer enzyme immunoassay for antibody IgM to HIV-1 p17 antigen.

Authors:  S Hashida; S Ishikawa; I Nishikata; K Hashinaka; S Oka; E Ishikawa
Journal:  J Clin Lab Anal       Date:  1998       Impact factor: 2.352

4.  Optimal conditions of immune complex transfer enzyme immunoassays for antibody IgGs to HIV-1 using recombinant p17, p24, and reverse transcriptase as antigens.

Authors:  S Hashida; S Ishikawa; K Hashinaka; I Nishikata; S Oka; K Shimada; A Saito; A Takamizawa; H Shinagawa; E Ishikawa
Journal:  J Clin Lab Anal       Date:  1998       Impact factor: 2.352

5.  Ultrasensitive and rapid enzyme immunoassay (thin aqueous layer immune complex transfer enzyme immunoassay) for antibody IgG to HIV-1 p17 antigen.

Authors:  S Ishikawa; S Hashida; K Hashinaka; A Adachi; S Oka; E Ishikawa
Journal:  J Clin Lab Anal       Date:  1998       Impact factor: 2.352

6.  More sensitive immune complex transfer enzyme immunoassay for antibody IgG to p17 of HIV-1 with shorter incubation time for immunoreactions and larger volumes of serum samples.

Authors:  S Ishikawa; S Hashida; K Hashinaka; M Kojima; A Saito; A Takamizawa; H Shinagawa; S Oka; K Shimada; E Ishikawa
Journal:  J Clin Lab Anal       Date:  1997       Impact factor: 2.352

7.  Potential of the immune complex transfer enzyme immunoassay for antigens and antibodies to improve the sensitivity and its limitations.

Authors:  E Ishikawa; S Ishikawa; S Hashida; K Hashinaka
Journal:  J Clin Lab Anal       Date:  1998       Impact factor: 2.352

Review 8.  More reliable diagnosis of infection with human immunodeficiency virus type 1 (HIV-1) by detection of antibody IgGs to pol and gag proteins of HIV-1 and p24 antigen of HIV-1 in urine, saliva, and/or serum with highly sensitive and specific enzyme immunoassay (immune complex transfer enzyme immunoassay): a review.

Authors:  S Hashida; K Hashinaka; S Ishikawa; E Ishikawa
Journal:  J Clin Lab Anal       Date:  1997       Impact factor: 2.352

9.  Preparations of recombinant HIV-1 p66 antigen to improve the specificity of immune complex transfer enzyme immunoassay of antibody IgG to HIV-1 reverse transcriptase.

Authors:  K Hashinaka; I Nishikata; S Hashida; A Adachi; S Oka; E Ishikawa
Journal:  J Clin Lab Anal       Date:  2000       Impact factor: 2.352

10.  Recombinant p51 as antigen in an immune complex transfer enzyme immunoassay of immunoglobulin G antibody to human immunodeficiency virus type 1.

Authors:  K Hashinaka; S Hashida; I Nishikata; A Adachi; S Oka; E Ishikawa
Journal:  Clin Diagn Lab Immunol       Date:  2000-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.