Literature DB >> 8926377

Assessment of the efficacy of a low temperature hydrogen peroxide gas plasma sterilization system.

M S Kyi1, J Holton, G L Ridgway.   

Abstract

The STERRAD 100 sterilization system (Johnson & Johnson Medical Ltd) uses low temperature hydrogen peroxide gas plasma for sterilization of heat labile equipment. The efficacy of the machine was tested by contaminating a standard set of instruments with different organisms and using a filtration method to assess recovery of organisms from the wash fluids of instruments post-sterilization. Experiments were performed under clean (the organism only) and dirty (organism mixed with egg protein) conditions. A parallel study conducted using a 3M STERIVAC ethylene oxide sterilizer could not be completed owing to closure of the ethylene oxide plant. For sterilization of instruments with long and narrow lumens, hydrogen peroxide adaptors are necessary. The STERRAD 100 sterilizer can achieve effective sterilization of heat labile instruments with a reduction of 6 log10 cfu/mL of organisms tested. This method has the advantages over ethylene oxide sterilization of safety, ease of maintenance and no requirement for aeration time.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8926377     DOI: 10.1016/0195-6701(95)90206-6

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  5 in total

1.  Effect of atmospheric pressure non-equilibrium plasmas on Neisseria gonorrhoeae.

Authors:  Yating Tu; Li Xu; Ying Yu; Ming Tan; Juan Li; Hongxiang Chen
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2010-04-21

2.  Bacteriological and mechanical impact of the Sterrad sterilization method on personalized 3D printed guides for mandibular reconstruction.

Authors:  Romain Bosc; Lionel Tortolano; Barbara Hersant; Moussa Oudjhani; Céline Leplay; Paul L Woerther; Paola Aguilar; Ronan Leguen; Jean-Paul Meningaud
Journal:  Sci Rep       Date:  2021-01-12       Impact factor: 4.379

3.  Resistance of 3D-Printed Components, Test Specimens and Products to Work under Environmental Conditions-Review.

Authors:  Marcin Głowacki; Adam Mazurkiewicz; Małgorzata Słomion; Katarzyna Skórczewska
Journal:  Materials (Basel)       Date:  2022-09-05       Impact factor: 3.748

Review 4.  Review of Disinfection and Sterilization - Back to the Basics.

Authors:  Jin Hong Yoo
Journal:  Infect Chemother       Date:  2018-06

Review 5.  A narrative review on current duodenoscope reprocessing techniques and novel developments.

Authors:  Maarten Heuvelmans; Herman F Wunderink; Henny C van der Mei; Jan F Monkelbaan
Journal:  Antimicrob Resist Infect Control       Date:  2021-12-23       Impact factor: 4.887

  5 in total