Literature DB >> 8922329

PTCA in angulated segments: effects of balloon material, balloon length, and inflation sequence on straightening forces in an in vitro model.

E Barasch1, J L Conger, K A Kadipasaoglu, J J Peters, K Nesdahl, J G Fenimore, J M Wilson, W K Vaughn, J J Ferguson.   

Abstract

We sought to determine the effect of balloon material, balloon length, and inflation sequence on the straightening forces generated during percutaneous transluminal coronary angioplasty (PTCA) in angulated segments. Using an in vitro model consisting of a curved channel (3/4" radius) with a displaceable pressure sensor, we examined four different balloon materials: compliant (POC), semicompliant (PE600 and Duralyn), and noncompliant (PET), two balloon lengths (20 mm and 40 mm), and two inflation sequences (rapid and slow) with continuous recording of straightening force during each balloon inflation. Three balloons were tested for each combination of materials, length, and inflation sequence. Long balloons exerted significantly lower straightening forces. There were significantly higher straightening forces with noncompliant, particularly short, balloons. Varying the inflation sequence had no significant effect. For PTCA in angulated segments: (1) long balloons produce lower straightening force, (2) noncompliant balloons produce higher straightening force, particularly with short balloons, and (3) varying the inflation sequence has no significant effect on straightening force.

Entities:  

Mesh:

Year:  1996        PMID: 8922329     DOI: 10.1002/(SICI)1097-0304(199610)39:2<207::AID-CCD23>3.0.CO;2-C

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  2 in total

1.  Evaluation of the differences in pressure applied to the vessel wall by different types of balloon remodeling microcatheters in an experimental model.

Authors:  Mizuka Ikezawa; Takashi Izumi; Masahiro Nishihori; Tetsuya Tsukada; Yosuke Tamari; Yoshio Araki; Kinya Yokoyama; Kenji Uda; Shunsaku Goto; Asuka E Kropp; Takafumi Otsuka; Naoki Kato; Mizuki Nakano; Ryuta Saito
Journal:  Interv Neuroradiol       Date:  2021-09-13       Impact factor: 1.764

2.  Numerical model of a valvuloplasty balloon: in vitro validation in a rapid-prototyped phantom.

Authors:  Benedetta Biffi; Giorgia M Bosi; Valentina Lintas; Rod Jones; Spyros Tzamtzis; Gaetano Burriesci; Francesco Migliavacca; Andrew M Taylor; Silvia Schievano; Giovanni Biglino
Journal:  Biomed Eng Online       Date:  2016-04-12       Impact factor: 2.819

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.