Feasibility of atrial fibrillation detection and use of a preceding synchronization interval as a criterion for shock delivery in humans with atrial fibrillation.

J S Sra1, C Maglio, A Dhala, Z Blanck, M Biehl, S Deshpande, E T Keelan, M R Jazayeri, M Akhtar.   

Abstract

OBJECTIVES: This study assessed the feasibility of detecting atrial fibrillation (AF) and delivery of appropriately timed R wave shocks using an implantable atrial defibrillator.
BACKGROUND: For atrial defibrillation therapy to be feasible in an implantable form, AF must be detected in a specific fashion, and the risk of ventricular proarrhythmia should be minimized.
METHODS: Eleven patients with AF underwent testing with an implantable atrial defibrillator (METRIX 3000 Automatic Atrial Defibrillator, InControl, Inc.). Wideband electrograms (EGMs) were recorded from the right ventricular (RV) bipolar catheter and from the multipolar catheters located in the right atrium (RA) and coronary sinus (CS). Atrial fibrillation detection was performed using two serial algorithms-quiet interval analysis and baseline crossing analysis-that detect atrial activity on the RA-CS channel. Ventricular sensing using a minimal preceding synchronization interval of 500 ms as a criterion for synchronous shock delivery was performed from filtered RV and RV-CS EGMs.
RESULTS: The AF detection algorithms were applied to 53 AF data segments and 18 normal sinus rhythm data segments. Atrial fibrillation was detected appropriately in 49 instances, and the specificity for detecting AF and normal sinus rhythm was 100%. Synchronization criterion efficacy was assessed by delivering shock markers and shocks. Of the 2,025 R waves processed, 557 (27.5%) were marked as suitable for shock delivery. In addition, 69 therapeutic and 11 test shocks were delivered during AF. All shock markers and shocks were delivered synchronously with the R wave, and the synchronization criterion was never violated.
CONCLUSIONS: Atrial fibrillation can be detected in a specific fashion using the RA-CS lead configuration and serial detection algorithms for atrial sensing. The delivery of properly timed shocks is feasible and should minimize the risk of ventricular proarrhythmia.

Entities:  

Mesh:

Year:  1996        PMID: 8917268     DOI: 10.1016/s0735-1097(96)00357-9

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  3 in total

Review 1.  Clinical experience with implantable atrial and combined atrioventricular defibrillators.

Authors:  W Jung; C Wolpert; B Esmailzadeh; S Spehl; S Herwig; B Schumacher; T Lewalter; H Omran; R Schimpf; C Vahlhaus; A Welz; B Lüderitz
Journal:  J Interv Card Electrophysiol       Date:  2000-01       Impact factor: 1.900

2.  Implantable atrial defibrillator and detection of atrial flutter.

Authors:  M Schwartz; C Maglio; M Akhtar; J Sra
Journal:  J Interv Card Electrophysiol       Date:  2000-04       Impact factor: 1.900

Review 3.  [Atrial defibrillator].

Authors:  W Jung; B Lüderitz
Journal:  Herz       Date:  1998-06       Impact factor: 1.443

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.