Literature DB >> 8916316

Instrument- and computer-related problems and artifacts in nuclear medicine.

M K O'Connor1.   

Abstract

Advances in gamma-camera design over the last 5 to 10 years have improved all aspects of image quality, particularly for tomographic imaging. As system complexity increases, it becomes more important that both the technologist and physician be able to recognize the various types of artifacts that can occur in gamma-camera systems and their potential impact on clinical studies. A thorough evaluation of the system at installation and a comprehensive quality control program will detect most problems that can occur. The most sensitive indicator of gamma-camera performance is uniformity. Because this measurement is performed on a daily basis, it is the principle tool in evaluating the status of the gamma-camera. Most artifacts related to the integrity of the detector head, computer system, and hard copy device can be detected on the uniformity image. For tomographic imaging, a quantitative determination of uniformity is needed to ensure that the system will not introduce ring artifacts into the patient data. Unlike planar imaging, the complex nature of tomographic imaging requires additional checks on system performance to ensure that other components of the system, such as the collimator, gantry, and imaging table, are not a source of artifact in the reconstructed image data. Failure of a system component can occur at any time and may be subtle and difficult to recognize in modern systems. In such an environment it becomes imperative that any unexpected finding in a clinical study be questioned with respect to a possible malfunction of some aspect of data acquisition and analysis.

Entities:  

Mesh:

Year:  1996        PMID: 8916316     DOI: 10.1016/s0001-2998(96)80003-1

Source DB:  PubMed          Journal:  Semin Nucl Med        ISSN: 0001-2998            Impact factor:   4.446


  7 in total

1.  Single photon-emission computed tomography.

Authors:  Thomas A Holly; Brian G Abbott; Mouaz Al-Mallah; Dennis A Calnon; Mylan C Cohen; Frank P DiFilippo; Edward P Ficaro; Michael R Freeman; Robert C Hendel; Diwakar Jain; Scott M Leonard; Kenneth J Nichols; Donna M Polk; Prem Soman
Journal:  J Nucl Cardiol       Date:  2010-10       Impact factor: 5.952

Review 2.  Collimator integrity.

Authors:  Frank P DiFilippo; Sue H Abreu; Haresh Majmundar
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

Review 3.  Single Photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging Guidelines: Instrumentation, Acquisition, Processing, and Interpretation.

Authors:  Sharmila Dorbala; Karthik Ananthasubramaniam; Ian S Armstrong; Panithaya Chareonthaitawee; E Gordon DePuey; Andrew J Einstein; Robert J Gropler; Thomas A Holly; John J Mahmarian; Mi-Ae Park; Donna M Polk; Raymond Russell; Piotr J Slomka; Randall C Thompson; R Glenn Wells
Journal:  J Nucl Cardiol       Date:  2018-10       Impact factor: 5.952

4.  "Picture-in-Picture" Artifact in Post-therapeutic 131I Whole-body Survey: Deceiving Spot View but Unraveling Whole-body Scanning.

Authors:  Mohsen Qutbi; Reyhane Ahmadi
Journal:  Mol Imaging Radionucl Ther       Date:  2022-06-27

5.  Evaluation of external beam hardening filters on image quality of computed tomography and single photon emission computed tomography/computed tomography.

Authors:  Nivedita Rana; Dinesh Rawat; Madan Parmar; Devinder Kumar Dhawan; Ashok Kumar Bhati; Bhagwant Rai Mittal
Journal:  J Med Phys       Date:  2015 Oct-Dec

6.  "Picture-in-Picture" Artifact: Introduction and Characterization of a Hitherto Unrecognized Imaging Artifact in Creating Perfusion Defects in Myocardial Perfusion Single-Photon Emission Computed Tomography.

Authors:  Mohsen Qutbi; Mehdi Soltanshahi; Saba Karami Gorzi; Yaser Shiravand; Seyed Mojtaba Edalat Haghi; Ali Khosravi; Isa Neshandar Asli
Journal:  Indian J Nucl Med       Date:  2021-03-04

7.  Assessment of Inter-modality Spatial Alignment Accuracy in Hybrid Single Photon Emission Computed Tomography in Patients with Hand and Wrist Pain.

Authors:  Cheng Xie; Gopinath Gnanasegaran; Hosahalli Mohan; Lefteris Livieratos
Journal:  World J Nucl Med       Date:  2013-09
  7 in total