Literature DB >> 891579

Safe amounts of contrast medium for angiocardiography in neonates and infants.

K M Fox, R G Patel, M Bonvicini, J F Taylor, G R Graham.   

Abstract

The results were analysed of 485 (biplane) cineangiocardiograms performed in 200 consecutive cardiac investigations on neonates (under 4 wk) and infants (4 wk to 1 yr). 10 deaths occurred during or within 24 h of cardiac catheterization, all in patients who were profoundly acidemic because of their hemodynamic disturbance. A total dose of Cardio-Conray at any one investigation of 4-5 ml/kg body weight was satisfactory and without undue risk. Single injections of 1.5-2.0 ml/kg body weight were safe whilst providing optimal diagnostic information. The interval between multiple injections did not appear to affect the risk to the patients.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 891579

Source DB:  PubMed          Journal:  Eur J Cardiol        ISSN: 0301-4711


  2 in total

1.  Risk of nephropathy after consumption of nonionic contrast media by children undergoing cardiac angiography: a prospective study.

Authors:  Ghloamhossein Ajami; Ali Derakhshan; Hamid Amoozgar; Mohammad Mohamadi; Mohammad Borzouee; Mitra Basiratnia; Saeid Abtahi; Sirous Cheriki; Manochehr Soltani
Journal:  Pediatr Cardiol       Date:  2010-02-27       Impact factor: 1.655

2.  Contrast administration in pediatric cardiac catheterization: dose and adverse events.

Authors:  Selvi Senthilnathan; Kimberlee Gauvreau; Audrey C Marshall; James E Lock; Lisa Bergersen
Journal:  Catheter Cardiovasc Interv       Date:  2009-05-01       Impact factor: 2.692

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.