The objectives of this trial are to assess the safety and effectiveness of the prosthesis and to establish the ability of the dilatable band to provide a nonsurgical option for dilatation. Forty-six patients received dilatable bands. All had congenital heart defects requiring banding of the main pulmonary artery. Dilatation was performed on 7 patients. This was successful in 6 and uncomplicated in all. In one patient the dilatable band was adjusted too tightly at implantation. In one patient the band was adjusted to loosely. In 7 patients the dilatable band was placed too distally and partially obstructed the right or left pulmonary artery. Distal migration of the dilatable band after implantation did not occur. One band was distorted during implantation. This did not compromise its function. Surgical sepsis resulted in a mycotic aneurysm and erosion of the pulmonary artery in one patient. Surgical pulmonary arterioplasty was performed in all 18 patients who had total correction and in 11 of the 13 patients who had bidirectional Glenn procedure and Damus-Stanzell connection. There were 13 deaths. None of the deaths were related to the dilatable band. Thirty-two prostheses were surgically explanted readily and completely in 31 patients. Five bands were removed at postmortem examination. Examination of all 37 of the dilatable bands revealed no evidence of wear or damage. Scanning electron microscopy evaluation was conducted on 5 of the explanted devices which had been implanted 158 to 1139 (mean 422) days. No component failure was identified. The dilatable band prostheses was effective and safe and provided a non-surgical option for dilatation.

Entities:  

Mesh:

Year:  1996        PMID: 8915722     DOI: 10.1007/bf01806224

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  36 in total

1.  The development of a prosthesis for banding of an artery capable of staged dilatation by intraluminal balloon dilator: an experimental investigation.

Authors:  D J Vince; G Culham; G Taylor
Journal:  J Thorac Cardiovasc Surg       Date:  1987-04       Impact factor: 5.209

2.  Balloon-dilatable arterial banding prosthesis: experimental study.

Authors:  D J Vince; J A Culham; G P Taylor
Journal:  Radiology       Date:  1987-07       Impact factor: 11.105

3.  Diminution and closure of large ventricular septal defects after pulmonary artery banding.

Authors:  Z G Mesko; J E Jones; A S Nadas
Journal:  Circulation       Date:  1973-10       Impact factor: 29.690

4.  Observations on the development of subaortic stenosis following pulmonary artery banding.

Authors:  A Rosenthal; M D Freed; D C Fyler; S B Litwin
Journal:  Chest       Date:  1974-04       Impact factor: 9.410

5.  Failure of pulmonary artery banding due to migration of the band.

Authors:  D Verel; D G Taylor; J L Emery
Journal:  Thorax       Date:  1970-01       Impact factor: 9.139

6.  High takeoff of the left main coronary artery from the pulmonary trunk: potentially fatal combination with pulmonary trunk banding.

Authors:  H F Steussy; R L Caldwell; E R Wills; B F Waller
Journal:  Am Heart J       Date:  1984-09       Impact factor: 4.749

7.  Bands inside the pulmonary artery. A complication of the Dammann-Muller procedure.

Authors:  J Rohmer; A G Brom; J Nauta
Journal:  Ann Thorac Surg       Date:  1967-05       Impact factor: 4.330

8.  Results of pulmonary arterial banding in infancy. Survey of 5 years' experience in the New England Regional Infant Cardiac Program.

Authors:  K J Dooley; L Parisi-Buckley; D C Fyler; A S Nadas
Journal:  Am J Cardiol       Date:  1975-10-06       Impact factor: 2.778

9.  The Fontan operation. Ventricular hypertrophy, age, and date of operation as risk factors.

Authors:  J K Kirklin; E H Blackstone; J W Kirklin; A D Pacifico; L M Bargeron
Journal:  J Thorac Cardiovasc Surg       Date:  1986-12       Impact factor: 5.209

10.  Pulmonary artery banding.

Authors:  R A Albus; G A Trusler; T Izukawa; W G Williams
Journal:  J Thorac Cardiovasc Surg       Date:  1984-11       Impact factor: 5.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.