Dimension of the periimplant mucosa. Biological width revisited.

T Berglundh1, J Lindhe.   

Abstract

The objective of the present study was to determine the dimension of the mucosal-implant attachment at sites with insufficient width of the ridge mucosa. 5 beagle dogs were used. Extractions of all mandibular premolars were performed and 3 months later, 3 fixtures of the Branemark System were installed in each side. Following 3 months of healing, abutment connection was carried out. On the right or left side of the mandible, abutment connection was performed according to the Branemark System manual (control side). On the contralateral side (test side), an incision not extending through the periosteum was made at the crest of the ridge. The soft tissue was dissected and a critical amount of connective tissue on the inside of the flap was excised. The periosteum was subsequently incised, abutment connection performed, and the trimmed flaps sutured. The sutures were removed after 10 days. After a 6-month period of plaque control, the animals were sacrificed, biopsies sampled and processed for light microscopy. The length of the junctional epithelium varied within a rather narrow range; 2.1 mm (control side) and 2.0 mm (test side). The height of the suprabony connective tissue in this model varied between 1.3+/-0.3 mm (test side) and 1.8+/-0.4 mm (control side). At sites where the ridge mucosa prior to abutment connection was made thin (< or = 2 mm), wound healing consistently included bone resorption. This implies that a certain minimum width of the periimplant mucosa may be required, and that bone resorption may take place to allow a stable soft tissue attachment to form.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8915028     DOI: 10.1111/j.1600-051x.1996.tb00520.x

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  58 in total

1.  Marginal bony changes in relation to different vertical positions of dental implants.

Authors:  Jung-Myung Yi; Jae-Kwan Lee; Heung-Sik Um; Beom-Seok Chang; Min-Ku Lee
Journal:  J Periodontal Implant Sci       Date:  2010-10-31       Impact factor: 2.614

2.  Distance between implants has a potential impact of crestal bone resorption.

Authors:  Matteo Danza; Ilaria Zollino; Anna Avantaggiato; Alessandra Lucchese; Francesco Carinci
Journal:  Saudi Dent J       Date:  2011-02-19

Review 3.  Bone level changes around platform switching and platform matching implants: a systematic review with meta-analysis.

Authors:  M DI Girolamo; R Calcaterra; R DI Gianfilippo; C Arcuri; L Baggi
Journal:  Oral Implantol (Rome)       Date:  2016-11-13

Review 4.  Epithelial integrins with special reference to oral epithelia.

Authors:  H Larjava; L Koivisto; L Häkkinen; J Heino
Journal:  J Dent Res       Date:  2011-03-25       Impact factor: 6.116

5.  In vitro assessment of the soft tissue/implant interface using porcine gingival explants.

Authors:  Aous A Abdulmajeed; Jaana Willberg; Stina Syrjänen; Pekka K Vallittu; Timo O Närhi
Journal:  J Mater Sci Mater Med       Date:  2015-01-15       Impact factor: 3.896

6.  Cystic epithelial lining seen around a dental implant: A case report of a rare finding.

Authors:  Yazad Gandhi; Neel Bhatavadekar
Journal:  J Oral Biol Craniofac Res       Date:  2020-07-03

7.  Mucosal dehiscence coverage for dental implant using split pouch technique: a two-stage approach [corrected].

Authors:  Toyohiko Hidaka; Daisuke Ueno
Journal:  J Periodontal Implant Sci       Date:  2012-06-30       Impact factor: 2.614

8.  Prosthetic Abutment Height is a Key Factor in Peri-implant Marginal Bone Loss.

Authors:  P Galindo-Moreno; A León-Cano; I Ortega-Oller; A Monje; F Suárez; F ÓValle; S Spinato; A Catena
Journal:  J Dent Res       Date:  2014-03-12       Impact factor: 6.116

9.  Platform switching vs standard implants in partially edentulous patients using the Dental Tech Implant System: clinical and radiological results from a prospective multicenter study.

Authors:  Massimo Del Fabbro; Carlo Bianchessi; Riccardo Del Lupo; Luca Landi; Silvio Taschieri; Stefano Corbella
Journal:  Clin Oral Investig       Date:  2015-03-31       Impact factor: 3.573

10.  Revisiting peri-implant soft tissue - histopathological study of the peri-implant soft tissue.

Authors:  Eduarda Silva; Sérgio Félix; Alberto Rodriguez-Archilla; Pedro Oliveira; José Martins dos Santos
Journal:  Int J Clin Exp Pathol       Date:  2014-01-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.