Literature DB >> 8903489

Localization of impalpable breast lesions--a surgical approach.

G Q della Rovere1, J R Benson, M Morgan, R Warren, A Patel.   

Abstract

The conventional approach to localization of impalpable breast lesions, i.e. employing a hooked wire with either stereotaxis or a perforated plate, has potential disadvantages for the operating surgeon. Often the entry point of the wire lies some distance from the site of projection of the lesion on the skin. The guide-wire should pierce the skin at, or close to, the site of any proposed surgical incision and proceed along the shortest and most direct course towards the lesion. Ideally, the wire should lie within a radial distance of between 1 and 2 cm from its target. A method is described which achieves these objectives and involves both radiological and clinical measurements. A total of 665 guide-wire localized biopsies have been carried out at the above institutions between 1 November 1987 and 31 March 1995 and between 1 January 1994 and 31 March 1996. In only 4% of cases was re-positioning of the wire required. Excision of the radiological lesion was obtained with a single biopsy in 99% of cases. A second or third biopsy was indicated in 0.7% and 0.3% of cases, respectively. Migration of the wire occurred in two patients and no cases of wire transection or pneumothorax were reported. This method of localization facilitates subsequent excision and permits the most appropriate incision consistent with optimal cosmesis.

Entities:  

Mesh:

Year:  1996        PMID: 8903489     DOI: 10.1016/s0748-7983(96)92853-x

Source DB:  PubMed          Journal:  Eur J Surg Oncol        ISSN: 0748-7983            Impact factor:   4.424


  4 in total

1.  Radioguided occult lesion localization versus wire-guided localization for non-palpable breast lesions: randomized controlled trial.

Authors:  Koray Ocal; Ahmet Dag; Ozgur Turkmenoglu; Emel Ceylan Gunay; Erdem Yucel; Meltem Nass Duce
Journal:  Clinics (Sao Paulo)       Date:  2011       Impact factor: 2.365

2.  Usefulness of hook wire localization biopsy under imaging guidance for nonpalpable breast lesions detected radiologically.

Authors:  Imrana Masroor; Shaista Afzal; Gulnaz Shafqat; Hasan Rehman
Journal:  Int J Womens Health       Date:  2012-08-31

3.  Dislocability of localization devices for nonpalpable breast lesions: experimental results.

Authors:  David Kaul; Eva Fallenberg; Felix Diekmann; Volker Budach; Martin Maurer
Journal:  Radiol Res Pract       Date:  2014-03-06

4.  Assessment of Ultrasound / Radio-guided Occult Lesion Localization in Non-palpable Breast Lesions.

Authors:  Seyed Ali Alamdaran; Donia Farokh; Ayda Sharifi Haddad; Navid Daghighi; Elaheh Modoodi; Ramin Sadeghi; Mohammad Naser Forghani; Asieh Sadat Fattahi
Journal:  Asia Ocean J Nucl Med Biol       Date:  2018
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.