Literature DB >> 8903454

Transthoracic bioimpedance can measure extravascular lung water in acute lung injury.

D M Nierman1, D I Eisen, E D Fein, E Hannon, J I Mechanick, E Benjamin.   

Abstract

We used a porcine endotoxemic model of acute lung injury to compare extravascular lung water (EVLW) measured by right transthoracic bioimpedance to postmortem gravimetric EVLW measurements. Adult pigs were randomized into control (N = 5) or endotoxin groups [150 microgram/kg Escherichia coli lipopolysaccharide B for 1 hr followed by 3 hr of resuscitation for a thermodilution cardiac output less than 90% of baseline using either isotonic saline (N = 5) or isooncotic albumin (N = 5)]. Right lung resistance was measured using a novel electrode array and a highly sensitive analyzer and was used to calculate right lung resistivity. At the end of the experiment, animals in the endotoxin-albumin group had higher gravimetric EVLWs than those in the endotoxin-saline or control groups (P < 0.05). Right lung resistivity corrected for body weight significantly correlated with gravimetric EVLW (r2 = 0.49; SEE = 0.96; P = 0.0038). Using multiple regression analysis, a predictive equation for EVLW based on right lung resistivity, body weight, and mean pulmonary artery pressure was generated (r2 = 0.81; SEE = 0.60; P < 0.0001). These results demonstrate that right lung resistivity measurements can provide a noninvasive estimate of EVLW. In addition, crystalloid may be preferable to colloid for fluid resuscitation in noncardiogenic pulmonary edema.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8903454     DOI: 10.1006/jsre.1996.0350

Source DB:  PubMed          Journal:  J Surg Res        ISSN: 0022-4804            Impact factor:   2.192


  5 in total

1.  Prediction of cardiogenic pulmonary edema onset by monitoring right lung impedance.

Authors:  Michael Shochat; Gideon Charach; Shmuel Meyler; Simcha Meisel; Moshe Weintraub; Galina Mengeritsky; Morris Mosseri; Pavel Rabinovich
Journal:  Intensive Care Med       Date:  2006-06-15       Impact factor: 17.440

2.  The measurement of lung water.

Authors: 
Journal:  Crit Care       Date:  1999       Impact factor: 9.097

Review 3.  Non-Invasive Monitoring of Cardiac Output in Critical Care Medicine.

Authors:  Lee S Nguyen; Pierre Squara
Journal:  Front Med (Lausanne)       Date:  2017-11-20

4.  Volumetric electromagnetic phase-shift spectroscopy of brain edema and hematoma.

Authors:  Cesar A Gonzalez; Jose A Valencia; Alfredo Mora; Fernando Gonzalez; Beatriz Velasco; Martin A Porras; Javier Salgado; Salvador M Polo; Nidiyare Hevia-Montiel; Sergio Cordero; Boris Rubinsky
Journal:  PLoS One       Date:  2013-05-14       Impact factor: 3.240

5.  Preventive treatment of alveolar pulmonary edema of cardiogenic origin.

Authors:  Gideon Charach; Michael Shochat; Alexander Rabinovich; Oded Ayzenberg; Jacob George; Lior Charach; Pavel Rabinovich
Journal:  J Geriatr Cardiol       Date:  2012-12       Impact factor: 3.327

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.