Literature DB >> 8902437

Diagnosis of premature rupture of the membranes in preterm patients, using an improved AFP kit: comparison with ROM-check and/or nitrazine test.

T Kishida1, H Yamada, H Negishi, T Sagawa, S Makinoda, S Fujimoto.   

Abstract

OBJECTIVE: We developed a new kit for detecting AFP in leaked amniotic fluid. Later, we developed an improved AFP kit utilizing the same anti alpha-fetoprotein (AFP) monoclonal antibody. In this study, we evaluate the clinical usefulness of this improved kit in the diagnosis of preterm premature rupture of membranes (PROM).
METHODS: We compared this improved AFP test with the ROM-check and/or the nitrazine tests in 46 preterm patients.
RESULTS: The ROM-check and nitrazine tests showed a diagnostic accuracy of 89.1 and 87.0%, respectively, compared with 95.7% with the improved AFP test. The sensitivity of the improved AFP test on cervical samples was significantly higher than that of the nitrazine test on vaginal samples (P < 0.05). The reaction time with the improved AFP kit test is 90 s.
CONCLUSION: This study has confirmed a great clinical utility of the improved AFP test kit as a method of PROM diagnosis.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8902437     DOI: 10.1016/0301-2115(95)02519-7

Source DB:  PubMed          Journal:  Eur J Obstet Gynecol Reprod Biol        ISSN: 0301-2115            Impact factor:   2.435


  8 in total

1.  The clinical significance of a positive Amnisure test in women with term labor with intact membranes.

Authors:  Seung Mi Lee; Joonho Lee; Hyo Suk Seong; Si Eun Lee; Joong Shin Park; Roberto Romero; Bo Hyun Yoon
Journal:  J Matern Fetal Neonatal Med       Date:  2009-04

2.  Contemporary diagnosis and management of preterm premature rupture of membranes.

Authors:  Aaron B Caughey; Julian N Robinson; Errol R Norwitz
Journal:  Rev Obstet Gynecol       Date:  2008

3.  Alpha-foetoprotein in the diagnosis of prelabour rupture of membranes.

Authors:  Chhavi Rana Singh; Rajeshwari Gurumoorthy Bhat
Journal:  J Clin Diagn Res       Date:  2014-11-20

4.  A transcervical amniotic fluid collector: a new medical device for the assessment of amniotic fluid in patients with ruptured membranes.

Authors:  Seung Mi Lee; Roberto Romero; Joong Shin Park; Piya Chaemsaithong; Jong Kwan Jun; Bo Hyun Yoon
Journal:  J Perinat Med       Date:  2015-07       Impact factor: 1.901

5.  Use of cervicovaginal fluid for the identification of biomarkers for pathologies of the female genital tract.

Authors:  Geert Zegels; Geert Aa Van Raemdonck; Wiebren Aa Tjalma; Xaveer Wm Van Ostade
Journal:  Proteome Sci       Date:  2010-12-08       Impact factor: 2.480

6.  Guidelines for the management of spontaneous preterm labor: identification of spontaneous preterm labor, diagnosis of preterm premature rupture of membranes, and preventive tools for preterm birth.

Authors:  Gian Carlo Di Renzo; Lluis Cabero Roura; Fabio Facchinetti; Aris Antsaklis; Gregor Breborowicz; Eduard Gratacos; Peter Husslein; Ronnie Lamont; Anton Mikhailov; Nuno Montenegro; Nebojsa Radunovic; Mike Robson; Stephen C Robson; Cihat Sen; Andrew Shennan; Florin Stamatian; Yves Ville
Journal:  J Matern Fetal Neonatal Med       Date:  2011-03-02

7.  Diagnosis of premature rupture of membranes by assessment of urea and creatinine in vaginal washing fluid.

Authors:  Nourossadat Kariman; Maryam Afrakhte; Mehdi Hedayati; Masoumeh Fallahian; Hamid Alavi Majd
Journal:  Iran J Reprod Med       Date:  2013-02

8.  The diagnostic power of cervico-vaginal fluid prolactin in the diagnosis of premature rupture of membranes.

Authors:  N Kariman; M Hedayati; Sh Alavi Majd
Journal:  Iran Red Crescent Med J       Date:  2012-09-30       Impact factor: 0.611