Literature DB >> 8899194

The dielectrophoresis enrichment of CD34+ cells from peripheral blood stem cell harvests.

M Stephens1, M S Talary, R Pethig, A K Burnett, K I Mills.   

Abstract

There is considerable interest in isolating the CD34+ cell population from leukaemic patients undergoing peripheral blood stem cell harvests. The techniques currently available make use of antibodies specific to the CD34+ surface markers. However, all of these techniques involve disturbance of the cell surface, are time-consuming and relatively expensive. In this study, we have used dielectrophoresis, which does not rely on the presence of cell-specific markers, to separate CD34+ cells from peripheral blood stem cell harvest samples containing an untreated natural mixed cell population. The separation is achieved by exploiting differences in the inherent dielectric properties of the various cell types. Samples obtained from peripheral blood stem cell harvests were resuspended in medium with a conductivity of less than 50 microS/cm and introduced into the dielectrophoretic separation chamber. Alternating field frequencies, from 500 kHz to 5 kHz, were used to collect cell fractions which were analysed by FACS, using a CD34-specific antibody, to quantify the CD34+ population within the fractions. On average a nearly five-fold increase in the frequency of the CD34+ cell population was observed in the fractions collected within the 50-10 kHz range. For this dielectrophoretic separation technique to be suitable in harvesting CD34+ cells for transplantation, it is important to demonstrate that the cells remain viable after the separation process. Cells obtained from each fraction grew when plated in colony assay cultures, GM-CFU and BFU-E, demonstrating that the cells remain normal, viable and capable of colony formation when cultured for 2 weeks. The number of colonies formed correlated with the percentage of CD34+ cells in each fraction. The dielectrophoretic separation technique is simple to operate, the separation is fast, the procedure non-invasive and although not tested has the potential to be incorporated as a batch-wise online facility with the standard harvesting equipment to increase the yield and speed of CD34+ cells in the PBSC harvest.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8899194

Source DB:  PubMed          Journal:  Bone Marrow Transplant        ISSN: 0268-3369            Impact factor:   5.483


  35 in total

1.  Separation of submicron bioparticles by dielectrophoresis.

Authors:  H Morgan; M P Hughes; N G Green
Journal:  Biophys J       Date:  1999-07       Impact factor: 4.033

2.  The removal of human breast cancer cells from hematopoietic CD34+ stem cells by dielectrophoretic field-flow-fractionation.

Authors:  Y Huang; J Yang; X B Wang; F F Becker; P R Gascoyne
Journal:  J Hematother Stem Cell Res       Date:  1999-10

3.  Differential analysis of human leukocytes by dielectrophoretic field-flow-fractionation.

Authors:  J Yang; Y Huang; X B Wang; F F Becker; P R Gascoyne
Journal:  Biophys J       Date:  2000-05       Impact factor: 4.033

4.  Electrorotation studies of baby hamster kidney fibroblasts infected with herpes simplex virus type 1.

Authors:  S Archer; H Morgan; F J Rixon
Journal:  Biophys J       Date:  1999-05       Impact factor: 4.033

Review 5.  Particle separation by dielectrophoresis.

Authors:  Peter R C Gascoyne; Jody Vykoukal
Journal:  Electrophoresis       Date:  2002-07       Impact factor: 3.535

Review 6.  Blood-on-a-chip.

Authors:  Mehmet Toner; Daniel Irimia
Journal:  Annu Rev Biomed Eng       Date:  2005       Impact factor: 9.590

7.  Efficient dielectrophoretic cell enrichment using a dielectrophoresis-well based system.

Authors:  Mohd Azhar Abdul Razak; Kai F Hoettges; Henry O Fatoyinbo; Fatima H Labeed; Michael P Hughes
Journal:  Biomicrofluidics       Date:  2013-12-04       Impact factor: 2.800

8.  Investigating dielectric properties of different stages of syngeneic murine ovarian cancer cells.

Authors:  Alireza Salmanzadeh; Michael B Sano; Roberto C Gallo-Villanueva; Paul C Roberts; Eva M Schmelz; Rafael V Davalos
Journal:  Biomicrofluidics       Date:  2013-01-23       Impact factor: 2.800

Review 9.  Separation of neural stem cells by whole cell membrane capacitance using dielectrophoresis.

Authors:  Tayloria N G Adams; Alan Y L Jiang; Prema D Vyas; Lisa A Flanagan
Journal:  Methods       Date:  2017-08-31       Impact factor: 3.608

10.  Membrane dielectric changes indicate induced apoptosis in HL-60 cells more sensitively than surface phosphatidylserine expression or DNA fragmentation.

Authors:  Xujing Wang; Frederick F Becker; Peter R C Gascoyne
Journal:  Biochim Biophys Acta       Date:  2002-08-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.