Literature DB >> 889522

[Present situation of hinge-type artificial knee joints (author's transl)].

W Blauth, G Bontemps, W Skripitz.   

Abstract

The introduction explains the general problems of knee joint replacement by artificial hinge-type prostheses, due to the reduction of the physiological "degrees of freedom" to only rotational movements around a horizontal axis. These problems are compared with the advantages of this type of prosthesis. Subsequently a description of some significant constructional characteristics of the hinge-type prosthesis, 13 given as there are placement of the joint, size of the contact surface, safety of the rotational device, design of the hinge-mechanism, the patella shield and the prosthetic stems as well as the breaking of dynamic forces, which all are subsequently compared in their values. Finally a hinge-type prosthesis is described with characteristics judged optimal according to our present scientific knowledge. We statistically evaluated our material of hinge-type prostheses with regard to final results and frequency of serious complications.

Entities:  

Mesh:

Year:  1977        PMID: 889522     DOI: 10.1007/bf00416616

Source DB:  PubMed          Journal:  Arch Orthop Unfallchir        ISSN: 0003-9330


  42 in total

1.  Arthroplasty of the knee joint employing an acrylic prosthesis.

Authors:  B WALLDIUS
Journal:  Acta Orthop Scand       Date:  1953

2.  The Walldius hinge arthroplasty.

Authors:  H Phillips; J G Taylor
Journal:  J Bone Joint Surg Br       Date:  1975-02

3.  [Partial and total endoprosthetic management of the knee joint. Differential indication and results].

Authors:  K Tillmann; G Bontemps; G Meier
Journal:  Z Orthop Ihre Grenzgeb       Date:  1975-08

4.  Biomechanical study of the hinge knee prosthesis. Preliminary report.

Authors:  J Wagner; R Bourgois
Journal:  Clin Orthop Relat Res       Date:  1974 Jul-Aug       Impact factor: 4.176

5.  [Mechanics of the knee-joint. 1 (author's transl)].

Authors:  A Menschik
Journal:  Z Orthop Ihre Grenzgeb       Date:  1974-06

6.  Performance of a hinged metal knee prosthesis. A case report with a follow-up of three and one-half years and histological and metallurgical data.

Authors:  D V Girzadas; S Geens; M L Clayton; J D Leidholt
Journal:  J Bone Joint Surg Am       Date:  1968-03       Impact factor: 5.284

7.  [Our clinical experiences with Guépar total knee prosthesis (author's transl)].

Authors:  H Ritter; W Overbeck
Journal:  Arch Orthop Unfallchir       Date:  1974-04-30

8.  [Intracondylar total knee-joint endoprosthesis "Modell St. George"].

Authors:  H W Buchholz; E Engelbrecht
Journal:  Chirurg       Date:  1973-08       Impact factor: 0.955

9.  Total knee replacement. A preliminary report using methylmethacrylate cement in 38 consecutive knees.

Authors:  P A Casagrande; R R Turner
Journal:  Clin Orthop Relat Res       Date:  1972       Impact factor: 4.176

10.  [Fat embolism following the use of bone cement in hip joint prosthesis. Animal experiments].

Authors:  H O Dustmann; K P Schulitz; H Koch
Journal:  Arch Orthop Unfallchir       Date:  1972
View more
  1 in total

1.  Unhooking of GSB total knee during dislocation of the patella.

Authors:  R Brückl; W Plitz; A N Witt
Journal:  Arch Orthop Trauma Surg       Date:  1979-06-29
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.