Abstract

Cultured cells subjected to fluid flow are exposed to mechanical forces and electrokinetic forces. The convective current establishes an electrokinetic force created by the flow-dependent transport of mobile ions in the media over the charged cell surfaces. This current can be expressed as a current density, the current normalized by the cross-sectional area in which it exists. In this study, we hypothesized that the convective current density has no role in the bone cell real-time intracellular calcium response to fluid flow. Our hypothesis was tested by incorporating electrokinetic measurements and classical electrokinetic double-layer theory to estimate the value of convective current density in a parallel-plate flow chamber and then to apply an external current during the presence of fluid flow that would alter convective current density. There was no difference between the mean peak calcium response of cells exposed to flow with an altered (canceled or doubled) convective current density versus flow with an unmodified convective current density, as was measured with fura-2 fluorescence microscopy. These results suggest that mechanical forces, such as fluid-induced shear stress, rather than concomitant electrokinetic forces are the primary stimuli in eliciting the observed calcium response of bone cells to fluid flow.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8894920     DOI: 10.1016/0021-9290(96)84535-0

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  7 in total

1.  The role of osteocytes in bone mechanotransduction.

Authors:  A Santos; A D Bakker; J Klein-Nulend
Journal:  Osteoporos Int       Date:  2009-06       Impact factor: 4.507

Review 2.  Biomechanics and mechanobiology of trabecular bone: a review.

Authors:  Ramin Oftadeh; Miguel Perez-Viloria; Juan C Villa-Camacho; Ashkan Vaziri; Ara Nazarian
Journal:  J Biomech Eng       Date:  2015-01       Impact factor: 2.097

3.  A fluid-structure interaction model to characterize bone cell stimulation in parallel-plate flow chamber systems.

Authors:  T J Vaughan; M G Haugh; L M McNamara
Journal:  J R Soc Interface       Date:  2013-01-30       Impact factor: 4.118

4.  Migration responses of outer and inner meniscus cells to applied direct current electric fields.

Authors:  Najmuddin J Gunja; Divya Dujari; Andrew Chen; Alba Luengo; Jason V Fong; Clark T Hung
Journal:  J Orthop Res       Date:  2011-06-27       Impact factor: 3.494

Review 5.  Biomechanical forces in the skeleton and their relevance to bone metastasis: biology and engineering considerations.

Authors:  Maureen E Lynch; Claudia Fischbach
Journal:  Adv Drug Deliv Rev       Date:  2014-08-29       Impact factor: 15.470

6.  Numerical test concerning bone mass apposition under electrical and mechanical stimulus.

Authors:  Diego A Garzón-Alvarado; Angélica M Ramírez-Martínez; Carmen Alicia Cardozo de Martínez
Journal:  Theor Biol Med Model       Date:  2012-05-11       Impact factor: 2.432

7.  Cellular fluid shear stress on implant surfaces-establishment of a novel experimental set up.

Authors:  P W Kämmerer; D G E Thiem; A Alshihri; G H Wittstock; R Bader; B Al-Nawas; M O Klein
Journal:  Int J Implant Dent       Date:  2017-05-31
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.