Wear debris has been implicated in the pathogenesis of loosening and osteolysis of total joint replacements by stimulating a foreign body and chronic inflammatory reaction capable of bone resorption. Whether increasing concentrations of wear particles have an adverse biological effect on bone has not been elucidated. We performed a histomorphological and semi-quantitative morphometric analysis of the reaction of bone to different concentrations of phagocytosable particles of high-density polyethylene (HDPE) and titanium 6-aluminium 4-vanadium alloy (Ti-6Al-4V) implanted in the rabbit tibia. The Ti-6Al-4V particles had a diameter of 4.0 +/- 4.4 microns (mean +/- SD); the HDPE particles averaged 4.7 +/- 2.1 microns. Suspensions of 10(6)-10(9) particles per ml were mixed in saline, sterilized, and introduced through a drill hole into the proximal tibia of 30 mature female rabbits. Controls included drilled, but non-implantable limbs. The animals were killed at 16 weeks and histological sections were made of the implant area. Histomorphological assessment was carried out using an interactive image analysis system. The parameters assessed included the presence of histiocytes, foreign body giant cells and inflammatory cells, the location and number of particles, the presence of haematopoeitic elements, fat or necrosis of the marrow, whether healing of the cortical window had taken place, and whether there was evidence of formation or resorption of bone by the periosteum, cortex and marrow. A semi-quantitative rating system was employed. Phagocytosable particles of Ti-6Al-4V and HDPE, in concentrations of 10(6)-10(9) particles per ml, evoked a histiocytic reaction without extensive fibrosis, necrosis or granuloma formation. This reaction occurred without disturbing the normal repair processes of bone formation and resorption to the surgical insult. A clear dose-response effect on the histological parameters assessed in this study was not noted. Using the present model, by 16 weeks, a similar "one time' particle load could be accommodated. The ongoing generation of particulate debris over a more extended period of time might be necessary before the remodelling processes of bone would be disturbed.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8894085     DOI: 10.1016/0142-9612(96)00013-0

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  7 in total

Review 1.  The biological response to orthopaedic implants for joint replacement: Part I: Metals.

Authors:  Emmanuel Gibon; Derek F Amanatullah; Florence Loi; Jukka Pajarinen; Akira Nabeshima; Zhenyu Yao; Moussa Hamadouche; Stuart B Goodman
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-06-21       Impact factor: 3.368

2.  Fibroblasts from the inner granulation tissue of the pseudocapsule in hips at revision arthroplasty induce osteoclast differentiation, as do stromal cells.

Authors:  H Sakai; S Jingushi; T Shuto; K Urabe; T Ikenoue; K Okazaki; T Kukita; A Kukita; Y Iwamoto
Journal:  Ann Rheum Dis       Date:  2002-02       Impact factor: 19.103

3.  Surface Damage on Dental Implants with Release of Loose Particles after Insertion into Bone.

Authors:  Plinio Senna; Altair Antoninha Del Bel Cury; Stephen Kates; Luiz Meirelles
Journal:  Clin Implant Dent Relat Res       Date:  2013-11-28       Impact factor: 3.932

4.  Effects of titanium particle size on osteoblast functions in vitro and in vivo.

Authors:  Moon G Choi; Hae S Koh; Daniel Kluess; Daniel O'Connor; Anshu Mathur; George A Truskey; Janet Rubin; David X F Zhou; K-L Paul Sung
Journal:  Proc Natl Acad Sci U S A       Date:  2005-03-08       Impact factor: 11.205

5.  Comparison of periprosthetic tissue digestion methods for ultra-high molecular weight polyethylene wear debris extraction.

Authors:  Ryan M Baxter; Marla J Steinbeck; Joanne L Tipper; Javad Parvizi; Michele Marcolongo; Steve M Kurtz
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2009-10       Impact factor: 3.368

Review 6.  How has the introduction of new bearing surfaces altered the biological reactions to byproducts of wear and modularity?

Authors:  Paul H Wooley
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

7.  Evidence for Gender-Specific Bone Loss Mechanisms in Periprosthetic Osteolysis.

Authors:  Renee T Ormsby; Lucian B Solomon; Roumen Stamenkov; David M Findlay; Gerald J Atkins
Journal:  J Clin Med       Date:  2019-12-24       Impact factor: 4.241

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.