Literature DB >> 8892260

Experimental test of theoretical models for time-resolved reflectance.

R Cubeddu1, A Pifferi, P Taroni, A Torricelli, G Valentini.   

Abstract

Four different expressions, derived from the diffusion theory or the random walk model, were used to fit time-resolved reflectance data for the evaluation of tissue optical properties. The experimental reflectance curves were obtained from phantoms of known optical parameters (absorption and transport scattering coefficients) covering the range of typical values for biological tissues between 600 and 900 nm. The measurements were performed using an instrumentation for time-correlated single-photon counting. The potential of the four methods in the assessment of the absorption and transport scattering coefficients was evaluated in terms of absolute error, linearity error, and dispersion of data. Each method showed different performances depending on the optical properties of the sample and the experimental conditions. We propose some criteria for the optimal choice of the fitting method to be used in different applications.

Mesh:

Year:  1996        PMID: 8892260     DOI: 10.1118/1.597739

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  18 in total

Review 1.  Non-invasive in vivo characterization of breast tumors using photon migration spectroscopy.

Authors:  B J Tromberg; N Shah; R Lanning; A Cerussi; J Espinoza; T Pham; L Svaasand; J Butler
Journal:  Neoplasia       Date:  2000 Jan-Apr       Impact factor: 5.715

2.  Optimal estimation reconstruction of the optical properties of a two-layered tissue phantom from time-resolved single-distance measurements.

Authors:  Fabrizio Martelli; Samuele Del Bianco; Lorenzo Spinelli; Stefano Cavalieri; Paola Di Ninni; Tiziano Binzoni; Alexander Jelzow; Rainer Macdonald; Heidrun Wabnitz
Journal:  J Biomed Opt       Date:  2015-11       Impact factor: 3.170

3.  Double-layer estimation of intra- and extracerebral hemoglobin concentration with a time-resolved system.

Authors:  Louis Gagnon; Claudine Gauthier; Rick D Hoge; Frédéric Lesage; Juliette Selb; David A Boas
Journal:  J Biomed Opt       Date:  2008 Sep-Oct       Impact factor: 3.170

4.  BabyLux device: a diffuse optical system integrating diffuse correlation spectroscopy and time-resolved near-infrared spectroscopy for the neuromonitoring of the premature newborn brain.

Authors:  Martina Giovannella; Davide Contini; Marco Pagliazzi; Antonio Pifferi; Lorenzo Spinelli; Rainer Erdmann; Roger Donat; Ignacio Rocchetti; Matthias Rehberger; Niels König; Robert Schmitt; Alessandro Torricelli; Turgut Durduran; Udo M Weigel
Journal:  Neurophotonics       Date:  2019-05-10       Impact factor: 3.593

5.  Probe-hosted silicon photomultipliers for time-domain functional near-infrared spectroscopy: phantom and in vivo tests.

Authors:  Rebecca Re; Edoardo Martinenghi; Alberto Dalla Mora; Davide Contini; Antonio Pifferi; Alessandro Torricelli
Journal:  Neurophotonics       Date:  2016-10-12       Impact factor: 3.593

6.  High throughput detection chain for time domain optical mammography.

Authors:  Edoardo Ferocino; Edoardo Martinenghi; Alberto Dalla Mora; Antonio Pifferi; Rinaldo Cubeddu; Paola Taroni
Journal:  Biomed Opt Express       Date:  2018-01-23       Impact factor: 3.732

7.  Instrument response function acquisition in reflectance geometry for time-resolved diffuse optical measurements.

Authors:  Ileana Pirovano; Rebecca Re; Alessia Candeo; Davide Contini; Alessandro Torricelli; Lorenzo Spinelli
Journal:  Biomed Opt Express       Date:  2019-12-13       Impact factor: 3.732

8.  Solid phantom recipe for diffuse optics in biophotonics applications: a step towards anatomically correct 3D tissue phantoms.

Authors:  Sanathana Konugolu Venkata Sekar; Andrea Pacheco; Pierluigi Martella; Haiyang Li; Pranav Lanka; Antonio Pifferi; Stefan Andersson-Engels
Journal:  Biomed Opt Express       Date:  2019-03-28       Impact factor: 3.732

9.  Coupling of cerebral blood flow and oxygen consumption during hypothermia in newborn piglets as measured by time-resolved near-infrared spectroscopy: a pilot study.

Authors:  Mohammad Fazel Bakhsheshi; Mamadou Diop; Laura B Morrison; Keith St Lawrence; Ting-Yim Lee
Journal:  Neurophotonics       Date:  2015-09-21       Impact factor: 3.593

10.  Accuracy and precision of tissue optical properties and hemodynamic parameters estimated by the BabyLux device: a hybrid time-resolved near-infrared and diffuse correlation spectroscopy neuro-monitor.

Authors:  Martina Giovannella; Lorenzo Spinelli; Marco Pagliazzi; Davide Contini; Gorm Greisen; Udo M Weigel; Alessandro Torricelli; Turgut Durduran
Journal:  Biomed Opt Express       Date:  2019-04-25       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.