Abstract

This present paper reports on experiments which seek to obtain evidence of the usefulness of vibration in the diagnosis of implant loosening by utilizing extra information by considering the amplitude response at all frequencies (within a certain range) as well as spectral analysis of particular waveforms. This frequency response is essentially a study of the manner in which the amplitude of vibration of a system varies as the frequency of an input force of fixed amplitude is varied. The experimental technique involved the application of a sinusoidal force to the distal end of a femur containing an implanted prosthesis and collecting the output signal using an accelerometer placed at the proximal end. The output signal was stored on a computer with a digital signal processing board and subsequently analysed using the two signal processing techniques mentioned above. Data were collected when the implanted prosthesis was secure, and at various stages of loosening. Analysis of these data shows that prosthetic instability can be detected using both modalities of vibration analysis.

Mesh:

Year:  1996        PMID: 8892245     DOI: 10.1016/1350-4533(96)00004-5

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  5 in total

1.  Knee Implant Loosening Detection: A Vibration Analysis Investigation.

Authors:  Arash Arami; Jean-Romain Delaloye; Hossein Rouhani; Brigitte M Jolles; Kamiar Aminian
Journal:  Ann Biomed Eng       Date:  2017-10-24       Impact factor: 3.934

Review 2.  Altering the Course of Technologies to Monitor Loosening States of Endoprosthetic Implants.

Authors:  João Henrique Cachão; Marco P Soares Dos Santos; Rodrigo Bernardo; António Ramos; Rainer Bader; Jorge A F Ferreira; António Torres Marques; José A O Simões
Journal:  Sensors (Basel)       Date:  2019-12-23       Impact factor: 3.576

3.  Experimental Investigation of Vibration Analysis on Implant Stability for a Novel Implant Design.

Authors:  Shouxun Lu; Benjamin Steven Vien; Matthias Russ; Mark Fitzgerald; Wing Kong Chiu
Journal:  Sensors (Basel)       Date:  2022-02-21       Impact factor: 3.576

4.  Investigation of a passive sensor array for diagnosis of loosening of endoprosthetic implants.

Authors:  Cathérine Ruther; Christian Schulze; Andrea Boehme; Hannes Nierath; Hartmut Ewald; Wolfram Mittelmeier; Rainer Bader; Daniel Kluess
Journal:  Sensors (Basel)       Date:  2012-12-20       Impact factor: 3.576

5.  Acoustic monitoring (RFM) of total hip arthroplasty - Results of a cadaver study.

Authors:  A C Unger; H Cabrera-Palacios; A P Schulz; Ch Jürgens; Andreas Paech
Journal:  Eur J Med Res       Date:  2009-06-18       Impact factor: 2.175