Management of humeral nonunion after the failure of locking intramedullary nails.

M D McKee1, M A Miranda, B L Riemer, R B Blasier, B J Redmond, S H Sims, J P Waddell, J B Jupiter.   

Abstract

We reviewed 21 cases of humeral nonunion following the failure of "locking" humeral nails. The nails had been inserted as the primary operative procedure following humeral fracture in fifteen cases or after the failure of closed treatment in six cases. Reconstruction after the failure of these implants was complicated by poor bone stock and difficulty in achieving union. Although technically difficult, open reduction and internal fixation with plating and bone grafting (successful in nine of nine cases) was more consistent than exchange nailing (successful in four of 10 cases) in achieving union (p = 0.01). Two patients refused further surgical intervention. The degree of bone loss associated with a loose nail, the lack of success of exchange nailing, and the insertion site morbidity associated with humeral nail removal differentiate these nonunions from similar lower extremity problems. The degree of bone loss following failed locking nailing of the humerus is a major concern, and exchange nailing alone may not be an acceptable option to deal with this problem.

Entities:  

Mesh:

Year:  1996        PMID: 8892150     DOI: 10.1097/00005131-199610000-00008

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  20 in total

1.  Shape memory Ni-Ti alloy swan-like bone connector for treatment of humeral shaft nonunion.

Authors:  Jia-Can Su; Xin-Wei Liu; Bao-Qing Yu; Zhuo-Dong Li; Ming Li; Chun-Cai Zhang
Journal:  Int Orthop       Date:  2009-02-07       Impact factor: 3.075

2.  Revision with plates of humeral nonunions secondary to failed intramedullary nailing.

Authors:  Christian Allende; Agustín Paz; Gonzalo Altube; Hernán Boccolini; Alejandro Malvarez; Bartolomé Allende
Journal:  Int Orthop       Date:  2013-11-21       Impact factor: 3.075

3.  A case series and review of salvage surgery for refractory humeral shaft nonunion following two or more prior surgical procedures.

Authors:  Todd A Borus; Edward H Yian; Madhav A Karunakar
Journal:  Iowa Orthop J       Date:  2005

Review 4.  Diaphyseal long bone nonunions - types, aetiology, economics, and treatment recommendations.

Authors:  Markus Rupp; Christoph Biehl; Matthäus Budak; Ulrich Thormann; Christian Heiss; Volker Alt
Journal:  Int Orthop       Date:  2017-12-22       Impact factor: 3.075

5.  Persistent non-union of the humeral shaft treated by plating and autologous bone grafting.

Authors:  Tristan Pollon; Nicolas Reina; Stéphanie Delclaux; Paul Bonnevialle; Pierre Mansat; Nicolas Bonnevialle
Journal:  Int Orthop       Date:  2016-08-10       Impact factor: 3.075

6.  Minimally invasive plate osteosynthesis in humerus nonunion after intramedullary nailing.

Authors:  Christian Allende; Fernando Vanoli; Luciano Gentile; Natalia Gutierrez
Journal:  Int Orthop       Date:  2018-03-24       Impact factor: 3.075

7.  Long-term follow-up of persistent humeral shaft non-unions treated with tricortical bone grafting and compression plating.

Authors:  A Billings; S S Coleman
Journal:  Iowa Orthop J       Date:  1999

8.  Locked intramedullary nailing for difficult nonunions of the humeral diaphysis.

Authors:  I Ilyas; D A Younge
Journal:  Int Orthop       Date:  2003-05-22       Impact factor: 3.075

9.  Free fibula flap for humerus segmental reconstruction: report on 13 cases.

Authors:  Roberto Adani; Luca Delcroix; Marco Innocenti; Luigi Tarallo; Alessio Baccarani
Journal:  Chir Organi Mov       Date:  2008-02-10

10.  Role of autologous non-vascularised intramedullary fibular strut graft in humeral shaft nonunions following failed plating.

Authors:  Sreekanth Kashayi-Chowdojirao; Aashish Vallurupalli; Vijay Krishna Chilakamarri; Chandrasekhar Patnala; Lalith Mohan Chodavarapu; Nageswara Rao Kancherla; Asif Hussain Khazi Syed
Journal:  J Clin Orthop Trauma       Date:  2016-12-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.