Literature DB >> 8891971

Biaxial long-stemmed multipronged distal components for revision/bone deficit total-wrist arthroplasty.

T K Cobb1, R D Beckenbaugh.   

Abstract

Revision total-wrist arthroplasty has a high incidence of complications. Loosening is a significant problem for the distal implant. Because of the high failure rate of single-pronged distal implants after revision total-wrist arthroplasty, a custom multipronged distal component (biaxial total-wrist implant) was designed for use in patients with deficient bone stock who undergo revision operation. Ten cases of total-wrist arthroplasty with a custom long-stemmed multipronged distal component are presented. The preoperative diagnosis was failed total-wrist arthroplasty in 9 cases. Mean time from previous total-wrist arthroplasty to revision procedure was 5.6 years. At follow-up evaluation (mean, 3.8 years; range, 3.0-4.8 years), 2 patients had undergone arthrodesis: 1 patient at an outside institution 1 year after surgery for periprosthetic fracture of the radius, and 1 patient at our institution for distal implant loosening. The 8 other patients had functional total-wrist arthroplasties. At follow-up evaluation, all patients reported they were satisfied. Six patients reported no pain and 2 reported mild pain. Mean range of motion at follow-up evaluation was within the previously defined limits that allow patients to function in activities of daily living: 78 degrees for supination, 77 degrees for pronation, 39 degrees for extension, 17 degrees for flexion, 12 degrees for radial deviation, and 18 degrees for ulnar deviation. Revision total-wrist arthroplasty with custom long-stemmed, multipronged distal components offers an alternative to those patients with deficient bone stock who refuse arthrodesis. Early results demonstrate greater longevity compared with single-pronged components for revision total-wrist arthroplasty.

Entities:  

Mesh:

Year:  1996        PMID: 8891971     DOI: 10.1016/S0363-5023(96)80189-4

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  7 in total

1.  Revision Total Wrist Arthroplasty Due to Polyethylene Wear, Metallosis-Induced Carpal Tunnel Syndrome, Distal Ulnar Impingement, and Fourth Carpometacarpal Joint Pain: Case Report and Pitfalls to Avoid.

Authors:  Fiesky A Nunez; Lauren Wright; Scott E Kilpatrick; William H Seitz
Journal:  Hand (N Y)       Date:  2018-11-12

2.  What Are the Risk Factors and Complications Associated With Intraoperative and Postoperative Fractures in Total Wrist Arthroplasty?

Authors:  Eric R Wagner; Jason J Srnec; Kapil Mehrotra; Marco Rizzo
Journal:  Clin Orthop Relat Res       Date:  2017-07-07       Impact factor: 4.176

3.  Promising clinical results of the universal total wrist prosthesis in rheumatoid arthritis.

Authors:  P J T S van Winterswijk; P A G M Bakx
Journal:  Open Orthop J       Date:  2010-02-17

4.  Survivorship of Revision Wrist Replacement.

Authors:  E M Pinder; K G Chee; M Hayton; S R Murali; S C Talwalkar; I A Trail
Journal:  J Wrist Surg       Date:  2017-05-15

5.  Universal 2 total wrist arthroplasty for the salvage of failed Biaxial total wrist arthroplasty.

Authors:  Hero J A Zijlker; Merel J Berkhout; Marco J P F Ritt; Niels van Leeuwen; Cees B IJsselstein
Journal:  J Hand Surg Eur Vol       Date:  2019-01-17

6.  Outcomes of Revision Total Wrist Arthroplasty.

Authors:  Eric R Wagner; Jason J Srnec; Michael W Fort; Laurel A Barras; Marco Rizzo
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2021-03-16

Review 7.  The instability of wrist joint and total wrist replacement.

Authors:  Jin-Xing Ma; Yong-Qing Xu
Journal:  Chin J Traumatol       Date:  2016