| Literature DB >> 8891928 |
H Ohtani1, H Kotaki, Y Sawada, T Iga.
Abstract
A high-performance liquid chromatographic (HPLC) method for the quantitative determination of epinastine, a non-sedating histamine H1 receptor antagonist, in rat plasma, was developed. A 100-microliters volume of plasma sample was spiked with a solution of internal standard (diphenidol) and extracted with dichloromethane under alkaline conditions. The extract was applied onto the HPLC system and detected by ultraviolet absorption at a wavelength of 220 nm. The linearity of the calibration curve was preserved over the concentration range of 20-1000 ng/ml. Both intra-assay variation and relative error were less than 5% for the plasma containing 50 ng/ml or 1000 ng/ml of epinastine hydrochloride. The analytical method presented here should be useful for the investigation of the pharmacokinetic properties of epinastine, which is of clinical significance.Entities:
Mesh:
Substances:
Year: 1996 PMID: 8891928 DOI: 10.1016/0378-4347(96)00094-1
Source DB: PubMed Journal: J Chromatogr B Biomed Appl ISSN: 1572-6495