Literature DB >> 8890829

Hemodynamic characteristics, myocardial kinetics and microvascular rheology of FS-069, a second-generation echocardiographic contrast agent capable of producing myocardial opacification from a venous injection.

D M Skyba1, G Camarano, N C Goodman, R J Price, T C Skalak, S Kaul.   

Abstract

OBJECTIVES: We sought to 1) study the effects of FS-069 on cardiac and systemic hemodynamic function, myocardial blood flow, left ventricular wall thickening and pulmonary gas exchange when injected intravenously; and 2) compare the myocardial kinetics and microvascular rheology of FS-069 and Albunex when injected directly into a coronary artery.
BACKGROUND: FS-069 is a second-generation echocardiographic contrast agent composed of perfluoropropane-filled albumin microspheres; it is capable of consistent and reproducible myocardial opacification from a venous injection.
METHODS: Nine dogs were used to study the effects of FS-069 on hemodynamic function, pulmonary gas exchange, left ventricular wall thickening and myocardial blood flow and to characterize its myocardial kinetics when injected intravenously. These dogs were also used to compare the myocardial kinetics of FS-069 with those of Albunex during intracoronary injections. Nine Sprague-Dawley rats were used to compare the microvascular rheology of these two contrast agents, and in vitro modeling was performed to assess whether the microvascular findings of FS-069 can explain its echocardiographic behavior during direct coronary injections.
RESULTS: There were no effects of 30 rapid venous injections of FS-069 (every 20 s) on cardiac output; mean aortic, pulmonary or left atrial pressures; and peak positive and negative first derivative of left ventricular pressure (dP/dt). Similarly, there were no effects of this agent on radiolabeled microsphere-measured regional myocardial blood flow, left ventricular wall thickening or pulmonary gas exchange. When injected intravenously, the myocardial transit of this agent resembled a gamma-variate form. When diluted FS-069 was injected directly into the coronary artery; however, its transit resembled the integral of gamma-variate function, with persistent myocardial opacification lasting several minutes, which was different from that of Albunex. Intravital microscopy revealed that, unlike Albunex, when no bubbles are entrapped within the microcirculation after an arterial injection, a very small fraction of the diluted, larger FS-069 microbubbles are entrapped. In vitro modeling confirmed that this small fraction of microbubbles can result in persistent myocardial opacification.
CONCLUSIONS: FS-069 produces no changes in hemodynamic function, myocardial blood flow, left ventricular wall thickening or pulmonary gas exchange when injected intravenously in large amounts. When diluted FS-069 is injected into the coronary artery, a very small fraction of the larger bubbles are entrapped within the microcirculation, resulting in a persistent contrast effect. Thus, although FS-069 is a safe intravenous echocardiographic contrast agent, it cannot provide information on myocardial blood flow when injected directly into a coronary artery.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8890829     DOI: 10.1016/S0735-1097(96)00328-2

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  12 in total

1.  Evaluation of myocardial, hepatic, and renal perfusion in a variety of clinical conditions using an intravenous ultrasound contrast agent (Optison) and second harmonic imaging.

Authors:  J Hancock; H Dittrich; D E Jewitt; M J Monaghan
Journal:  Heart       Date:  1999-06       Impact factor: 5.994

2.  Real-time measurement of renal blood flow in healthy subjects using contrast-enhanced ultrasound.

Authors:  Kambiz Kalantarinia; J Todd Belcik; James T Patrie; Kevin Wei
Journal:  Am J Physiol Renal Physiol       Date:  2009-07-22

Review 3.  Preparation of targeted microbubbles: ultrasound contrast agents for molecular imaging.

Authors:  Alexander L Klibanov
Journal:  Med Biol Eng Comput       Date:  2009-06-11       Impact factor: 2.602

4.  Safety of the transpulmonary ultrasound contrast agent NC100100: a clinical and haemodynamic evaluation in patients with suspected or proved coronary artery disease.

Authors:  Y Myreng; P Molstad; K Ytre-Arne; M Aas; L Stoksflod; J O Nossen; B Oftedal
Journal:  Heart       Date:  1999-09       Impact factor: 5.994

Review 5.  Ultrasound in Radiology: From Anatomic, Functional, Molecular Imaging to Drug Delivery and Image-Guided Therapy.

Authors:  Alexander L Klibanov; John A Hossack
Journal:  Invest Radiol       Date:  2015-09       Impact factor: 6.016

Review 6.  Molecular imaging of cardiovascular disease using ultrasound.

Authors:  Flordeliza S Villanueva
Journal:  J Nucl Cardiol       Date:  2008 Jul-Aug       Impact factor: 5.952

Review 7.  Ultrasound contrast materials in cardiovascular medicine: from perfusion assessment to molecular imaging.

Authors:  Alexander L Klibanov
Journal:  J Cardiovasc Transl Res       Date:  2013-08-03       Impact factor: 4.132

Review 8.  Ultrasound molecular imaging of cardiovascular disease.

Authors:  Flordeliza S Villanueva; William R Wagner
Journal:  Nat Clin Pract Cardiovasc Med       Date:  2008-08

Review 9.  Use of contrast echocardiography in intensive care and at the emergency room.

Authors:  Bernard Cosyns; Bram Roossens; Sophie Hernot; Philippe El Haddad; Herve Lignian; Luc Pierard; Patrizio Lancellotti
Journal:  Curr Cardiol Rev       Date:  2011-08

10.  Future applications of contrast ultrasound.

Authors:  Kevin Wei
Journal:  J Cardiovasc Ultrasound       Date:  2011-09-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.