Literature DB >> 8890017

Application of reduced-encoding imaging with generalized-series reconstruction (RIGR) in dynamic MR imaging.

S Chandra1, Z P Liang, A Webb, H Lee, H D Morris, P C Lauterbur.   

Abstract

Dynamic MRI has proven to be an important tool in studies of transient physiologic changes in animals and humans. High sensitivity and temporal resolution in such measurements are critical for accurate estimation of dynamic information. Fast imaging, often involving expensive hardware, has evolved for use in such cases. We demonstrate herein the possibility of accelerated data acquisition schemes on conventional machines using standard pulse sequences for dynamic studies. This is achieved by combining reduced-encoded dynamic data (typically 30 to 40 phase encodings) with a priori high-resolution data via a novel constrained image reconstruction algorithm. Such an approach reduces image acquisition time significantly (by a factor of 3 to 4 in the examples described here) without loss in the accuracy of information.

Entities:  

Mesh:

Year:  1996        PMID: 8890017     DOI: 10.1002/jmri.1880060512

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  6 in total

1.  Bayesian parallel imaging with edge-preserving priors.

Authors:  Ashish Raj; Gurmeet Singh; Ramin Zabih; Bryan Kressler; Yi Wang; Norbert Schuff; Michael Weiner
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

2.  Improved waveform fidelity using local HYPR reconstruction (HYPR LR).

Authors:  Kevin M Johnson; Julia Velikina; Yijing Wu; Steve Kecskemeti; Oliver Wieben; Charles A Mistretta
Journal:  Magn Reson Med       Date:  2008-03       Impact factor: 4.668

3.  Interleaved variable density sampling with a constrained parallel imaging reconstruction for dynamic contrast-enhanced MR angiography.

Authors:  Kang Wang; Reed F Busse; James H Holmes; Philip J Beatty; Jean H Brittain; Christopher J Francois; Scott B Reeder; Jiang Du; Frank R Korosec
Journal:  Magn Reson Med       Date:  2011-02-28       Impact factor: 4.668

4.  Keyhole chemical exchange saturation transfer.

Authors:  G Varma; R E Lenkinski; E Vinogradov
Journal:  Magn Reson Med       Date:  2012-01-13       Impact factor: 4.668

5.  Edge-enhanced spatiotemporal constrained reconstruction of undersampled dynamic contrast-enhanced radial MRI.

Authors:  Srikant Kamesh Iyer; Tolga Tasdizen; Edward V R Dibella
Journal:  Magn Reson Imaging       Date:  2012-03-28       Impact factor: 2.546

6.  Pulmonary perfusion MRI using interleaved variable density sampling and HighlY constrained cartesian reconstruction (HYCR).

Authors:  Kang Wang; Mark L Schiebler; Christopher J Francois; A Munoz Del Rio; Ma Daniela Cornejo; Laura C Bell; Frank R Korosec; Jean H Brittain; James H Holmes; Scott K Nagle
Journal:  J Magn Reson Imaging       Date:  2013-01-24       Impact factor: 4.813

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.