Literature DB >> 8889394

Evaluation of a novel stable whole blood quality control material for lymphocyte subset analysis: results from the UK NEQAS immune monitoring scheme.

D Barnett1, V Granger, P Mayr, I Storie, G A Wilson, J T Reilly.   

Abstract

The UK NEQAS immune Monitoring Scheme (UK NEQAS) evaluates the performance of laboratories routinely performing T-lymphocyte subset analysis on HIV-infected individuals. The scheme originally issued fresh whole blood, but a significant problem was that of analyte stability, especially 36 h postphlebotomy. To circumvent this problem, we have developed a novel stabilisation procedure that ensures retention of leucocyte light scatter and immunological staining characteristics for up to 300 days. In addition, the stabilised whole blood preparation is fully compatible with flow cytometer technology, incorporating either whole blood lysis or "no wash, no lyse" techniques. The ranges of interlaboratory coefficient of variation for the stabilised material are now tighter than those previously obtained with fresh whole blood. Development of this novel material has enabled overseas laboratories to participate in the UK NEQAS immune Monitoring Scheme and could in the future lead to the production of reference and/or calibration reagents for leucocyte immunophenotyping.

Entities:  

Mesh:

Year:  1996        PMID: 8889394     DOI: 10.1002/(SICI)1097-0320(19960915)26:3<216::AID-CYTO6>3.0.CO;2-C

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  6 in total

1.  Affordable CD4(+)-T-cell counting by flow cytometry: CD45 gating for volumetric analysis.

Authors:  George Janossy; Ilesh V Jani; Nicholas J Bradley; Arsene Bikoue; Tim Pitfield; Debbie K Glencross
Journal:  Clin Diagn Lab Immunol       Date:  2002-09

2.  A general method for bead-enhanced quantitation by flow cytometry.

Authors:  Martin Montes; Elin A Jaensson; Aaron F Orozco; Dorothy E Lewis; David B Corry
Journal:  J Immunol Methods       Date:  2006-10-10       Impact factor: 2.303

3.  VERITAS?: A time for VERIQAS™ and a new approach to training, education, and the quality assessment of CD4+ T lymphocyte counting (I).

Authors:  David Barnett; Liam Whitby; John Wong; Raul Louzao; John T Reilly; Thomas N Denny
Journal:  Cytometry B Clin Cytom       Date:  2011-10-13       Impact factor: 3.058

4.  Stabilization of Transfected Cells Expressing Low-Incidence Blood Group Antigens: Novel Methods Facilitating Their Use as Reagent-Cells.

Authors:  Cecilia González; Rosa Esteban; Carme Canals; Eduardo Muñiz-Díaz; Núria Nogués
Journal:  PLoS One       Date:  2016-09-07       Impact factor: 3.240

5.  Compatibility of stabilized whole blood products with CD4 technologies and their suitability for quality assessment programs.

Authors:  Tao Ding; Michèle Bergeron; Peggy Seely; Xuefen Yang; Tamsir O Diallo; Margot Plews; Paul Sandstrom; T Blake Ball; Adrienne F A Meyers
Journal:  PLoS One       Date:  2014-08-08       Impact factor: 3.240

6.  Preparation of Internal Quality Control Material for Lymphocyte Subset Analysis.

Authors:  Eun Youn Roh; Sue Shin; Jong Hyun Yoon; Sohee Oh; Kyoung Un Park; Nuri Lee; Eun Young Song
Journal:  Ann Lab Med       Date:  2016-07       Impact factor: 3.464

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.