Literature DB >> 8887010

Ultrasensitive and more specific enzyme immunoassay (immune complex transfer enzyme immunoassay) for p24 antigen of HIV-1 in serum using affinity-purified rabbit anti-p24 Fab' and monoclonal mouse anti-p24 Fab'.

S Hashida1, K Hashinaka, I Nishikata, A Saito, A Takamizawa, H Shinagawa, E Ishikawa.   

Abstract

Previously, an ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) for p24 antigen of HIV-1 was developed. The immune complex comprising 2,4-dinitrophenyl-biotinyl-bovine serum albumin-rabbit anti-p24 Fab' conjugate, p24 antigen, and rabbit anti-p24 Fab' -beta-D-galactosidase conjugate was trapped onto polystyrene beads coated with affinity-purified (anti-2,4-dinitrophenyl group) IgG, was eluted with epsilon N-2, 4-dintrophenyl-L-lysine, and was transferred to polystyrene beads coated with streptavidin. beta-D-Galactosidase activity bound to the streptavidin-coated polystyrene beads was assayed by fluorometry. This assay was highly sensitive. However, bound beta-D-galactosidase activity had to be assayed for a long time (20 h), and the nonspecific signal was observed in 5% serum samples from subjects with low risk of HIV infection. In the present study, the assay time for bound beta-D-galactosidase activity was shortened to 2.5 h by using 2,4-dinitrophenyl-biotinyl-bovine serum albumin-affinity-purified rabbit anti-p24 Fab' conjugate and affinity-purified rabbit anti-p24 Fab' -beta-D-galactosidase conjugate. Furthermore, the nonspecific signal was found to increase with increasing periods of time for storage of serum samples at -20 degrees C, and this increase was prevented without prolongation of the assay time for bound beta-D-galactosidase activity and without loss of the sensitivity by substituting monoclonal mouse anti-p24 Fab'-beta-D-galactosidase conjugate for affinity-purified rabbit anti-p24 Fab'beta-D-galactosidase conjugate.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8887010     DOI: 10.1002/(SICI)1098-2825(1996)10:5<302::AID-JCLA11>3.0.CO;2-0

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  13 in total

1.  Rapid formation of the immune complexes on solid phase in the immune complex transfer enzyme immunoassays for HIV-1 p24 antigen and antibody IgGs to HIV-1.

Authors:  S Ishikawa; S Hashida; K Hashinaka; A Adachi; S Oka; E Ishikawa
Journal:  J Clin Lab Anal       Date:  1998       Impact factor: 2.352

2.  Rapid and ultrasensitive enzyme immunoassay (thin aqueous layer immune complex transfer enzyme immunoassay) for HIV-1 p24 antigen.

Authors:  S Ishikawa; S Hashida; K Hashinaka; E Ishikawa
Journal:  J Clin Lab Anal       Date:  1998       Impact factor: 2.352

3.  Immune complex transfer enzyme immunoassay for antibody IgM to HIV-1 p17 antigen.

Authors:  S Hashida; S Ishikawa; I Nishikata; K Hashinaka; S Oka; E Ishikawa
Journal:  J Clin Lab Anal       Date:  1998       Impact factor: 2.352

4.  Optimal conditions of immune complex transfer enzyme immunoassays for antibody IgGs to HIV-1 using recombinant p17, p24, and reverse transcriptase as antigens.

Authors:  S Hashida; S Ishikawa; K Hashinaka; I Nishikata; S Oka; K Shimada; A Saito; A Takamizawa; H Shinagawa; E Ishikawa
Journal:  J Clin Lab Anal       Date:  1998       Impact factor: 2.352

5.  Ultrasensitive and rapid enzyme immunoassay (thin aqueous layer immune complex transfer enzyme immunoassay) for antibody IgG to HIV-1 p17 antigen.

Authors:  S Ishikawa; S Hashida; K Hashinaka; A Adachi; S Oka; E Ishikawa
Journal:  J Clin Lab Anal       Date:  1998       Impact factor: 2.352

6.  More sensitive immune complex transfer enzyme immunoassay for antibody IgG to p17 of HIV-1 with shorter incubation time for immunoreactions and larger volumes of serum samples.

Authors:  S Ishikawa; S Hashida; K Hashinaka; M Kojima; A Saito; A Takamizawa; H Shinagawa; S Oka; K Shimada; E Ishikawa
Journal:  J Clin Lab Anal       Date:  1997       Impact factor: 2.352

7.  Potential of the immune complex transfer enzyme immunoassay for antigens and antibodies to improve the sensitivity and its limitations.

Authors:  E Ishikawa; S Ishikawa; S Hashida; K Hashinaka
Journal:  J Clin Lab Anal       Date:  1998       Impact factor: 2.352

Review 8.  More reliable diagnosis of infection with human immunodeficiency virus type 1 (HIV-1) by detection of antibody IgGs to pol and gag proteins of HIV-1 and p24 antigen of HIV-1 in urine, saliva, and/or serum with highly sensitive and specific enzyme immunoassay (immune complex transfer enzyme immunoassay): a review.

Authors:  S Hashida; K Hashinaka; S Ishikawa; E Ishikawa
Journal:  J Clin Lab Anal       Date:  1997       Impact factor: 2.352

9.  Ultrasensitive immune complex transfer enzyme immunoassay of HIV-1 p24 antigen with less serum interference using 2,4-dinitrophenyl-anti-HIV-1 p24 IgG and indirectly immobilized (anti-2,4-dinitrophenyl group) Fab..

Authors:  S Ishikawa; S Hashida; K Hashinaka; A Saito; A Takamizawa; H Shinagawa; E Ishikawa
Journal:  J Clin Lab Anal       Date:  1999       Impact factor: 2.352

10.  Earlier detection of human immunodeficiency virus type 1 p24 antigen and immunoglobulin G and M antibodies to p17 antigen in seroconversion serum panels by immune complex transfer enzyme immunoassays.

Authors:  S Hashida; S Ishikawa; K Hashinaka; I Nishikata; S Oka; E Ishikawa
Journal:  Clin Diagn Lab Immunol       Date:  2000-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.