Literature DB >> 8885929

A comparison of umbilical cord blood gas values between newborns with and without true knots.

J T Maher1, J A Conti.   

Abstract

OBJECTIVE: To compare umbilical cord blood gas values in newborns with and without true knots, and to assess the potential impact of true knot formation on cord blood gases.
METHODS: Twelve newborn infants with true umbilical cord knots were identified and compared with a random control population of 104 newborn infants without true knots. The two groups were analyzed for 11 maternal-fetal variables to determine if they were comparable. Subsequently, the principal outcome variable of the study was evaluated: a comparison between the umbilical arterial and venous blood gas results of the true knot and control populations.
RESULTS: The true knot and control populations were comparable with respect to the maternal-fetal variables analyzed. The umbilical cord blood gas values did not differ between groups, except for a slightly lower umbilical artery bicarbonate value in the control group (22.0 mEq/L) versus the true knot group (24.5 mEq/L), P = .025. There was no significant difference in the incidence of acidemia (umbilical artery pH less than 7.20) between the two groups.
CONCLUSION: The presence of true umbilical cord knots does not alter the incidence of umbilical artery acidemia or change umbilical cord blood gas values. Review of the pertinent obstetric literature supports the hypothesis that true umbilical cord knots lack clinical significance.

Entities:  

Mesh:

Year:  1996        PMID: 8885929     DOI: 10.1016/0029-7844(96)00313-4

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  6 in total

1.  The hip trial: psychosocial consequences for mothers of using ultrasound to manage infants with developmental hip dysplasia.

Authors:  F Gardner; C Dezateux; D Elbourne; A Gray; A King; A Quinn
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2005-01       Impact factor: 5.747

Review 2.  Use of umbilical cord blood gas analysis in the assessment of the newborn.

Authors:  L Armstrong; B J Stenson
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2007-11       Impact factor: 5.747

3.  True umbilical cord knot leading to fetal demise.

Authors:  Ji Ikechebelu; Gu Eleje; Cj Ofojebe
Journal:  Ann Med Health Sci Res       Date:  2014-07

4.  True knot at the time of delivery: electronic fetal monitoring characteristics and neonatal outcomes.

Authors:  Ebony B Carter; Cheryl S Chu; Zach Thompson; Methodius G Tuuli; George A Macones; Alison G Cahill
Journal:  J Perinatol       Date:  2018-10-15       Impact factor: 2.521

5.  The Strategy against Iatrogenic Prematurity Due to True Umbilical Knot: From Prenatal Diagnosis Challenges to the Favorable Fetal Outcome.

Authors:  Roxana Elena Bohiltea; Valentin-Nicolae Varlas; Vlad Dima; Ana-Maria Iordache; Teodor Salmen; Bianca-Margareta Mihai; Alexia Teodora Bohiltea; Emilia Maria Vladareanu; Ioniță Ducu; Corina Grigoriu
Journal:  J Clin Med       Date:  2022-02-03       Impact factor: 4.241

6.  Umbilical Cord Knots: Is the Number Related to Fetal Risk?

Authors:  Guglielmo Stabile; Stefania Carlucci; Lucia De Bonis; Felice Sorrentino; Luigi Nappi; Giuseppe Ricci
Journal:  Medicina (Kaunas)       Date:  2022-05-25       Impact factor: 2.948

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.