Literature DB >> 8884914

Preparation of solid phantoms with defined scattering and absorption properties for optical tomography.

U Sukowski1, F Schubert, D Grosenick, H Rinneberg.   

Abstract

We have developed diffusely scattering solid phantoms with optical (scattering) properties amenable to theoretical calculations. Monodisperse quartz glass spheres were used as scatterers embedded in polyester resin. An infrared dye was added to simulate absorption by biological tissue. Solid phantoms were tested for their macroscopic homogeneity. Several phantoms were built with well-defined spatial variations in their transport scattering and absorption coefficients to be used for optical tomography. Scattering, transport scattering, and absorption coefficients of solid, homogeneous phantoms and of aqueous suspensions of monodisperse quartz glass spheres were derived from measurements of time-integrated collimated transmittance and time-resolved diffuse transmittance. For aqueous suspensions of monodisperse quartz glass spheres at known number density scattering and transport scattering coefficients calculated by Mie theory are in quantitative agreement with experimentally derived values. In addition, diffuse reflectance and diffuse transmittance of aqueous suspensions at various number densities were measured and found to be in excellent agreement with results of Monte Carlo calculations using theoretical values for the scattering coefficients and anisotropy parameters.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8884914     DOI: 10.1088/0031-9155/41/9/017

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  How to improve quality assurance in fluorometry: fluorescence-inherent sources of error and suited fluorescence standards.

Authors:  U Resch-Genger; K Hoffmann; W Nietfeld; A Engel; J Neukammer; R Nitschke; B Ebert; R Macdonald
Journal:  J Fluoresc       Date:  2005-05       Impact factor: 2.217

2.  Phantoms for diffuse optical imaging based on totally absorbing objects, part 1: Basic concepts.

Authors:  Fabrizio Martelli; Antonio Pifferi; Davide Contini; Lorenzo Spinelli; Alessandro Torricelli; Heidrun Wabnitz; Rainer Macdonald; Angelo Sassaroli; Giovanni Zaccanti
Journal:  J Biomed Opt       Date:  2013-06       Impact factor: 3.170

3.  Agarose-based Tissue Mimicking Optical Phantoms for Diffuse Reflectance Spectroscopy.

Authors:  Afrina Mustari; Izumi Nishidate; Md Abdul Wares; Takaaki Maeda; Satoko Kawauchi; Shunichi Sato; Manabu Sato; Yoshihisa Aizu
Journal:  J Vis Exp       Date:  2018-08-22       Impact factor: 1.355

4.  Dependence of optical scattering from Intralipid in gelatin-gel based tissue-mimicking phantoms on mixing temperature and time.

Authors:  Puxiang Lai; Xiao Xu; Lihong V Wang
Journal:  J Biomed Opt       Date:  2014-03       Impact factor: 3.170

Review 5.  Criteria for the design of tissue-mimicking phantoms for the standardization of biophotonic instrumentation.

Authors:  Lina Hacker; Heidrun Wabnitz; Antonio Pifferi; T Joshua Pfefer; Brian W Pogue; Sarah E Bohndiek
Journal:  Nat Biomed Eng       Date:  2022-05-27       Impact factor: 25.671

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.